Closed
Posted
Paid on delivery
My Dell PowerEdge M630 is throwing simultaneous faults for both the IO Module and the iDRAC in the Chassis Management Controller. These errors began right after I swapped in a new NDR Broadcom module and an RSPI card, so I suspect either firmware mismatch, configuration drift, or a seating/compatibility issue. Your task is to diagnose and clear those alerts, restore full iDRAC access, and bring the IO Module back online so everything shows green in the CMC. I can supply CMC screenshots, current firmware versions, and remote KVM access; if reseating or component swaps are needed, I’ll be on site to follow your instructions. Acceptance criteria • CMC recognises and reports the IO Module and iDRAC as healthy • Network ports tied to the IO Module come up and pass traffic • iDRAC web/SSH console is reachable and responsive • A brief step-by-step summary of the fix is delivered for future reference Experience with Dell OpenManage, Lifecycle Controller, and blade chassis troubleshooting will let you wrap this up quickly. Let me know the tools or firmware packages you’ll need and we can get started right away.
Project ID: 40688551
4 proposals
Remote project
Active 2 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
4 freelancers are bidding on average ₹8,500 INR for this job

As someone with over a decade of practical experience in Network Administration and Technical support, I firmly believe I can diagnose and resolve the errors on your Dell PowerEdge M630 impacting the IO module and iDRAC. Coupling my profound understanding with Dell OpenManage tools, Lifecycle Controller, and blade chassis troubleshooting, your issue will be resolved efficiently. I am well-versed in handling various vendors' equipment, including Dell, which would ensure seamless performance restoration for your system. Moreover, I understand the importance of providing clear and concise documentation of the work done for future reference. As requested in the project details, I will deliver a detailed summary outlining the steps undertaken ensuring that all acceptance criteria are met. My commitment to best practices ensures that any fixes not only bring immediate rectification but also promote long-term stability. To reiterate, selecting me for this task means putting your faith in someone who is experienced, detail-oriented and possesses top-notch technical skills. Rest assured, as soon as you let me know the requisite tools or firmware packages needed to get started, we'll hit the ground running! I look forward to the opportunity to work with you and resolve these technical challenges once and for all.
₹10,000 INR in 2 days
7.2
7.2

Hi there, I can see your PowerEdge M630 threw simultaneous IO Module and iDRAC faults right after dropping in that NDR Broadcom module and RSPI card — classic firmware mismatch or configuration drift after a hardware swap. I've handled dozens of Dell blade chassis issues and I know exactly where to look: Lifecycle Controller logs, CMC event history, and the actual firmware versions on each module to spot the conflict. What I'll do: ✅ Pull current firmware inventory via Lifecycle Controller and compare against compatible versions for your NDR Broadcom module ✅ Diagnose and clear the CMC alerts — restore healthy IO Module and iDRAC status in the chassis view ✅ Verify network ports tied to the IO Module come up and pass traffic ✅ Test everything before we close — backup current config first so nothing gets broken ✅ Deliver a step-by-step fix summary for future reference Skills: ✅ Dell PowerEdge M-series — iDRAC, CMC, Lifecycle Controller, OpenManage troubleshooting ✅ Firmware analysis, version compatibility checks, and staged updates ✅ NDR Broadcom module and RSPI card configuration and compatibility ✅ Network port validation and traffic testing ✅ Microsoft® Certified: MCSA | MCSE | MCT ✅ 300+ projects delivered, 280+ five-star reviews
₹7,000 INR in 2 days
6.5
6.5

Hi, The timing of these two faults is important. Since both the iDRAC and IO Module errors started immediately after the Broadcom NDR module and RSPI card change, I would troubleshoot the hardware change and chassis compatibility path first rather than treating them as separate failures. I have 18+ years of hands-on enterprise infrastructure experience across Dell-class server environments, virtualization, storage, networking, firmware and out-of-band management troubleshooting. I can work through the CMC and KVM remotely, identify whether the issue is firmware, configuration, compatibility or physical seating, and guide you through any on-site reseating or component swap that is required. I will stay through validation of iDRAC access, IO Module health and network traffic, and provide a short recovery summary afterward. Can you share the exact CMC fault messages currently shown for the iDRAC and IO Module? Regards, Varadarajan(Raj)
₹12,000 INR in 2 days
0.0
0.0

Ahmedabad, India
Member since Oct 11, 2025
$30-250 CAD
₹600-1500 INR
₹150000-250000 INR
$25-50 USD / hour
$30-250 USD
$250-750 USD
$8-15 USD / hour
$30-250 USD
$15-25 USD / hour
$30-250 USD
₹12500-37500 INR
min $50 USD / hour
$2-8 USD / hour
$50-85 AUD
$750-1500 USD
$30-250 CAD
£20-250 GBP
₹100-400 INR / hour
$46000-56000 CAD
$25-30 USD / hour