Closed
Posted
Paid on delivery
We are a Venezuelan engineering company developing an electric immersion heater for extra-heavy crude oil (tubular sheathed elements, U-shaped hairpins, in an ASME VIII pressure vessel). The thermal design is already done. We need an experienced heat-transfer / process engineer to REVIEW it and give an independent opinion — not to design from scratch. ▎ ▎ Service: ▎ - Crude: ~8 °API (Orinoco Belt), highly viscous, with 20–50 % emulsified water ▎ - Heating 70 → 85 °C, line pressure ~4.5 barg (design 10 barg / 200 °C) ▎ - Two models: 100 bbl/d (~9.5 kW) and 600 bbl/d (~53 kW) ▎ - Incoloy 825 sheath, Ø 0.475", no baffles (natural convection dominated) ▎ ▎ Questions to answer: ▎ 1. Is a watt density of ~1.5–1.7 W/in² reasonable for this service? What would you use and why? ▎ 2. Is "sheath temperature ≤ water saturation temperature at line pressure − 10 K" the right limiting criterion, or is it too conservative? ▎ 3. Film coefficient: natural convection in a confined tube bundle with viscous crude — what values and correction factor for bundle confinement would you expect? ▎ 4. Would you add baffles? Estimated effect on bundle size vs. pressure drop and fouling. ▎ 5. Is the design basis (ΔT 15 K, 50 % water cut, bare-body losses) appropriate? ▎ ▎ Deliverable: a short written report (3–6 pages) with your answers, your own numbers and references, plus one video call to discuss. ▎ We provide: a 3–4 page technical summary and our calculation sheet. ▎ ▎ Required: proven experience with heaters, heat exchangers or line heaters for heavy oil / bitumen / fuel oil (please describe a real project). Knowledge of natural convection correlations (Churchill–Chu, etc.). Spanish is a plus. ▎ An NDA will be required.
Project ID: 40766525
32 proposals
Remote project
Active 3 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
32 freelancers are bidding on average $517 USD for this job

At a 50 % water cut some water will settle out and the lowest hairpin legs may sit right in it. Saturation at about 5.5 bar absolute is roughly 155 °C so the minus 10 K rule caps the sheath near 145 °C. Natural convection in 8 °API crude may give only a few tens of W/m²K. At 1.7 W/in² the film rise could then be 40 to 80 K so the criterion may not be too conservative at all. I'd rerun the film coefficient on my own using crude viscosity at the film temperature. Then I'd answer all five questions with my own figures. Are the hairpins horizontal and how high do the lowest legs sit above the vessel bottom where free water would collect?
$750 USD in 7 days
7.6
7.6

Hi, Your thermal design is already prepared, so I will independently review the calculations rather than redesign the heater. I will check the 1.5-1.7 W/in² watt density, sheath-temperature limit, natural-convection film coefficient, Churchill-Chu correlation use, bundle confinement effects, baffle tradeoffs, fouling risk, water cut, ΔT, and heat losses. I will compare the two heater cases using clear numbers and references, then provide a practical 3-6 page report followed by the video call. My Electrical Engineering and Engineering background supports the heater and pressure-vessel review, while API requirements and Finite Element Analysis can be considered where they affect the design basis. I am also comfortable working under an NDA. Could you share the calculation sheet, crude viscosity data versus temperature, tube spacing, and the current natural-convection correlation assumptions so I can focus the review on the most uncertain values? Please start chat and let’s discuss the calculation sheet and the key assumptions.
$600 USD in 7 days
6.9
6.9

Hi, I can provide an independent calculation review of the two heater sizes, focused on the five decisions in your brief. I would reconcile the energy balance first, then examine sheath heat flux and film-temperature sensitivity using temperature-dependent fluid properties and the actual bundle geometry. The review would distinguish the water-related temperature limit from crude fouling/coking limits, check whether the selected natural-convection correlations apply to the stated geometry, and make any confinement correction explicit. I would compare the no-baffle basis with a baffled arrangement in terms of circulation, pressure loss, cleaning and fouling rather than assuming that a higher heat-transfer coefficient is always preferable. My USD 480 proposal covers the 3–6 page review with independent numbers, references, assumptions and sensitivity ranges, plus a discussion call, in 4 days after the calculation sheet and property data are available. My background is engineering modelling and analysis; I do not have a documented heavy-oil heater installation case to present as a reference. Do you have viscosity-versus-temperature data for the actual emulsion, and bundle spacing/orientation details? Best regards, Gökay
$480 USD in 4 days
6.8
6.8

Hi, I’m a mechanical engineer with 5 years of experience in mechanical design, thermal engineering, and engineering analysis. I can review your existing thermal design independently, focusing on the assumptions, calculation methodology, and risks associated with heating highly viscous crude oil containing emulsified water. My review would cover watt density, sheath-temperature limits, natural-convection correlations, bundle confinement effects, the potential benefits and drawbacks of baffles, and the sensitivity of the design basis to water cut, viscosity, and heat losses. I would compare your calculations against established heat-transfer correlations and relevant technical references, document my assumptions and independent calculations, and provide a concise report with recommendations and a video-call discussion. Before proceeding, I would like to clarify the crude-oil viscosity data versus temperature, the vessel and heater-bundle geometry, and the expected water-phase behavior, as these will strongly influence the natural-convection assessment. I should note that my background is in mechanical engineering and thermal analysis; I would be transparent about any limits in directly comparable heavy-crude immersion-heater projects. If proven project-specific experience is a strict prerequisite, I would welcome discussing whether my technical review capabilities fit your needs. Best regards,
$750 USD in 20 days
6.7
6.7

As an experienced multi-skilled Engineer with a successful track record in Engineering and CAD design, I bring a unique blend of expertise to your project. My background in Chemical and Electrical Engineering combined with my proficiency in Thermal Analysis, Fast Fourier Transform thermal simulation modules, gives me the ability to provide a comprehensive and well-informed review of your immersion heater design for heavy crude oil. During my tenure, I have worked on multiple projects similar to yours, involving heat exchangers, oil line heaters, and heavy oil/fuel oil heating systems. One such project I can recall is the design of an efficient heater system for a tar sand extraction facility. We encountered challenges of high viscosity and emulsified water, similar to those anticipated here; through methodical work and my understanding of parameters likeap watt density, sheath temperature restriction, film coefficients, and bare body losses, we managed to optimize the heater design significantly.
$266 USD in 1 day
6.2
6.2

As a versatile and highly skilled engineer, I have substantial hands-on experience in engineering and several areas, including electrical and mechanical engineering - skills deeply aligned with your project needs. I have an incredible familiarity with heaters, heat exchangers and line heaters for heavy oil, bitumen and fuel oil; also, I’ve developed numerous calculations regarding natural convection correlations like Churchill-Chu. This gives me the expertise to provide the robust analysis and independent perspective you need. Moreover, my range of software proficiencies including ArchiCAD, Revit, Tekla, Rhino, Abaqus, Keyshot10 (to name just a few) allows me to interpret complex thermal designs like yours effectively. My known aptitude in analyzing thermal performance and applying fitting values would be vital in answering your crucial project questions on watt density selection, sheath temperature criterion or need for baffles.
$250 USD in 3 days
6.3
6.3

Hello, I am an aerospace engineer with several years of experience in thermal-fluid engineering, heat transfer, and immersion heater analysis. I can independently review your existing design, validate key thermal assumptions, and provide practical, evidence-based recommendations. My review will cover watt density, sheath temperature limits, natural convection correlations for viscous crude, bundle configuration and baffles, and the overall design basis. You will receive a concise 3–6 page technical report with independent calculations, references, and actionable recommendations. I am ready to start upon receiving your calculation sheet and technical summary, and can sign an NDA beforehand. Best regards
$400 USD in 6 days
5.2
5.2

Hello, I can review your existing thermal design, evaluate the key assumptions, and prepare a concise technical report covering watt density, sheath temperature limits, natural convection, bundle confinement, baffles, and design basis. I’ll provide engineering calculations, recommendations, and relevant technical references, followed by a video call to discuss the findings. I’m happy to sign an NDA before reviewing your documents. Best regards
$500 USD in 7 days
4.9
4.9

I understand you need an independent review of your electric immersion heater's thermal design for heavy crude oil, similar to the Watt Density and Film Coefficient calculations I've performed for challenging viscous fluids in past projects. My expertise lies in validating complex heat transfer scenarios to ensure optimal performance and safety. My approach will involve a rigorous review of your thermal calculations, focusing on the heat transfer coefficients for your specific crude oil properties (viscosity, API gravity, water emulsion). I will analyze your U-shaped hairpin geometry, element watt density, and ASME VIII vessel parameters. This will include validating your film coefficient assumptions and checking for potential fouling or burnout risks. I'll utilize established heat transfer correlations and potentially perform simplified CFD analysis if discrepancies arise. Could you share the heat transfer correlations and boundary conditions used in your current design? I'm also curious about the expected service life and maintenance intervals for these units given the heavy crude. I'm available for a brief call to discuss how my review can provide you with the necessary independent assurance.
$587 USD in 21 days
4.3
4.3

Hi, Aashiq here from Cape Town, South Africa. This project instantly caught my eye, so I had to reach out. I see you’re looking for an experienced heat-transfer engineer to review your thermal design for an electric immersion heater. Your focus on specific watt densities and film coefficients in the context of heavy crude oil is really intriguing. I've worked on similar projects, helping companies optimize thermal systems for heavy oil applications. My experience includes assessing heat exchangers and heaters, leveraging natural convection correlations like Churchill–Chu. I’m confident I can provide the insights you need and would be happy to share samples of my work. Based on what you mentioned, here is how we would approach the project: - Review your thermal design against industry standards - Analyze the watt density and sheath temperature criteria - Evaluate the film coefficients and suggest any necessary corrections - Discuss the need for baffles and their impact on performance You can expect clear communication throughout the process, ensuring a seamless, user-focused solution optimized for performance. Best Regards, Aashiq
$700 USD in 14 days
3.6
3.6

Hello, I can assist with an independent technical review of your existing immersion heater calculations, focusing on thermal performance and design assumptions rather than redesigning the equipment. The review would examine the proposed watt density, sheath temperature limit, natural convection correlations, bundle confinement effects, baffle trade-offs, and the impact of water cut and heat losses. I would document calculations, assumptions, uncertainties, and supporting engineering references in a concise 3–6 page report. I can work under an NDA and include a technical discussion call. My proposed budget is $400 with a 5–7 day review period, subject to evaluating your calculation sheet. Could you share the technical summary and temperature-dependent crude viscosity data so I can assess the review scope?
$500 USD in 7 days
0.0
0.0

Hi, The unusual part of your project is the focus on thermal performance metrics like watt density and film coefficient for heavy crude oil immersion heaters, which is a specialized engineering challenge. While my background is primarily in AI and software systems, I understand the importance of precise modeling and validation in engineering projects. I would approach this by clarifying the physical parameters and boundary conditions critical to heat transfer analysis, ensuring the methodology aligns with process engineering standards. Understanding the data sources and validation methods will be key to assessing accuracy and reliability. This approach helps mitigate risks related to incorrect thermal load estimations or scaling issues. Best Regards Robert
$500 USD in 7 days
0.0
0.0

Hi, the key review is whether the proposed watt density and natural-convection assumptions remain valid for 8 °API crude with 20–50% emulsified water inside a confined, unbaffled tube bundle. I’d focus the independent assessment on sheath-temperature limits, the appropriate film-coefficient correlations and confinement corrections, and whether adding baffles would meaningfully improve heat transfer without creating excessive pressure drop or fouling risk. I can also examine the 15 K temperature rise, 50% water-cut design basis, and bare-body heat losses against the stated operating conditions. If you’re open to a review focused on rigorous calculations and technical references, please share the calculation sheet and design summary to establish the scope. Thanks.
$500 USD in 7 days
0.0
0.0

Watt density and film coefficient assumptions are the critical risks for your immersion electric heater in extra-heavy Orinoco crude (~8°API) with 20–50% emulsified water. My review approach: I’ll sanity-check your 1.5–1.7 W/in² selection against natural-convection boiling/incipient film limits in confined tubular geometry, then recompute h with viscous-property corrections and bundle-confinement factors, using classic correlations (e.g., Churchill–Chu) plus heat-transfer modeling consistent with sheathed Incoloy 825 elements and U-hairpins in an ASME VIII vessel. I will evaluate your limiting criterion (sheath ≤ saturation temperature at line pressure −10 K) for conservatism vs. realistic measurement location, and test whether ΔT=15 K and 50% water-cut/bare-body losses form a defensible design basis for 70→85°C (4.5 barg line; 10 barg design).
$500 USD in 7 days
0.0
0.0

Heat-transfer review for an immersion heater in heavy crude: I’m a strong skills match for (1) heat-transfer/thermal modeling logic, (2) critical parameter review (watt density, film coefficient, tube-bundle correlations), and (3) disciplined technical documentation with traceable assumptions. I can methodically sanity-check your Orinoco ~8°API service with 20–50% emulsified water, heating 70→85°C at ~4.5 barg (ASME VIII vessel). Although my core background is FPGA & embedded thermal modeling support, I use the same rigorous “requirements → calculations → verification” approach you need: check whether 1.5–1.7 W/in² watt density is defensible, validate your sheath-temperature limit vs water saturation minus 10 K, estimate natural-convection film coefficients for confined sheathed elements in viscous crude (Churchill–Chu and confinement/bundle corrections), and assess whether baffles would reduce film resistance versus increased bundle size, ΔP, and fouling risk.
$500 USD in 7 days
0.0
0.0

Natural convection and sheath temperature limits are the critical risks for your ASME VIII tubular immersion heater in heavy Orinoco crude (8 °API, 20–50% emulsion water). My approach: a focused thermal/heat-transfer review—not redesign—checking watt density targets (~1.5–1.7 W/in²), your temperature criterion (sheath ≤ Tsat@4.5 barg −10 K), and the implied film coefficient for viscous crude in a confined tubular bundle (U-shaped Incoloy 825 hairpins, no baffles). I will benchmark correlations (e.g., Churchill–Chu variants) and estimate bundle confinement correction factors, then evaluate whether baffles would materially improve h while trading off pressure drop and fouling potential, using your provided calc sheet plus my independent numbers. Deliverable: 3–6 page report with references and a 1-hour video call. If you share your exchanger geometry and property basis, I can start within 48h—ready to confirm scope under NDA.
$500 USD in 7 days
0.0
0.0

First 24–48 hours: I’ll review your existing thermal design sheet and assumptions (70→85 °C, ~4.5 barg line/10 barg design, 8°API viscous crude with 20–50% emulsified water, Incoloy 825 Ø0.475" U-hairpins, natural convection, ΔT=15 K, bare-body losses). Then I’ll map geometry to heat-transfer correlations and identify which variables dominate (wettability, effective viscosity, confinement, and evaporation limits). Next I’ll run an independent check focused on your exact questions: whether 1.5–1.7 W/in² watt density is defensible; if the sheath limit (≤ Tsat(P) −10 K) is overly conservative; expected film coefficient for viscous crude in a confined bundle using appropriate natural convection correlations (e.g., Churchill–Chu and confinement/bundle factors); and whether baffles are worth it versus pressure drop, fouling, and hydraulics. I’ll also verify the basis for 50% water-cut and compute revised numbers with references.
$500 USD in 7 days
0.0
0.0

Before vs after: you already have a thermal design—my job is to stress-test it so the watt density and film-coefficient assumptions hold for Orinoco 8°API extra-heavy crude with 20–50% emulsion water. After review, you’ll have independent numbers, the right limiting criterion for Incoloy 825 Ø0.475" U-hairpins in an ASME VIII vessel, and defensible heat-transfer coefficients for natural convection dominating (no baffles). I’ll evaluate 1.5–1.7 W/in² against viscosity-driven HTC ranges for confined heater bundles, apply/compare correlations (e.g., Churchill–Chu framework plus bundle confinement adjustments), and check whether “sheath temp ≤ line saturation temperature −10 K” is truly conservative at ~4.5 barg/85°C or overly restrictive. I’ll also comment on your ΔT=15 K, 50% water cut, bare-body losses basis; and quantify tradeoffs if adding baffles (size vs pressure drop/fouling).
$500 USD in 7 days
0.0
0.0

Dear Client, For this review, the key question is not whether the existing heater reaches 85 °C—it is whether the selected watt density, local sheath temperature and assumed natural-convection coefficient remain defensible once high viscosity, emulsion behaviour, bundle confinement and fouling are considered together. I have 11 years of experience in electronics, thermal-aware hardware design and multidisciplinary product development, so I would only take this assignment with an experienced heat-transfer/process engineer supporting the heavy-crude review. My approach: Calculation Audit → Fluid Properties → Natural-Convection Correlation → Bundle-Confinement Correction I would focus on validating the 1.5–1.7 W/in² loading, estimating realistic film coefficients across the 70–85 °C range, checking the water-saturation temperature margin, and determining whether baffles materially improve heat transfer without introducing unacceptable pressure drop or fouling. I can deliver an independent 3–6 page review covering assumptions, sensitivity cases, engineering references, followed by a technical video discussion. Question: 1. Do your calculations use temperature-dependent crude viscosity and thermal properties, or fixed design-point values? Profile: https://www.freelancer.in/u/ElectronicsMust If you message me, I can outline the three assumptions I would challenge first before accepting the current watt-density limit. Kind Regards, Avi Gupta Quality is never an accident
$450 USD in 7 days
0.0
0.0

Hi there, Your key need is an independent thermal review of the immersion-heater design for highly viscous, water-emulsified heavy crude, not a redesign from scratch. The critical checks are watt density, sheath-temperature limits, natural-convection film coefficients, bundle confinement, baffles, fouling, and the validity of the design basis. I have strong hands-on experience with Engineering and Electrical Engineering and have solved similar problems involving thermal equipment review, heat-transfer calculations, and industrial heating reliability. My approach would be to: * Review the technical summary, calculation sheet, geometry, operating conditions, and material assumptions. * Identify the root cause of any uncertainty and determine what can be reused versus what needs to be changed. * Implement a clean, maintainable solution using heat-transfer correlations, viscosity-sensitive property estimates, and engineering checks for the tubular elements. * Test edge cases, reliability, performance, safety, and integration behavior across both 100 and 600 bbl/d cases. * Deliver a concise 3-6-page report with independent numbers, references, recommendations, and discussion points for the video call. For natural convection, the effective viscosity and confined-bundle characteristic length must be handled consistently; otherwise Churchill-Chu results can materially overstate heat transfer and underpredict sheath temperature. I prefer fixing the actual root cause rather than
$600 USD in 7 days
0.0
0.0

Caracas, Venezuela
Payment method verified
Member since Oct 20, 2020
$250-750 USD
$15-25 USD / hour
$250-750 USD
$250-750 USD
$10-20 USD
$1500-3000 USD
$10-20 USD
$250-750 USD
₹12500-37500 INR
$125-250 CAD
$10000-20000 USD
$250-750 CAD
₹1500-12500 INR
$250-750 AUD
$30-250 USD
$15-25 AUD / hour
₹600-1500 INR
€750-1500 EUR
$15-25 USD / hour
₹750-1250 INR / hour
₹600-1500 INR
₹1500-12500 INR
$50-100 USD
$30-250 CAD