I need a compliant lighting layout for a small utility area that is under 100 m². The sole purpose is to keep workers safe when they access the space at night, so all calculations and mounting positions must meet Australian Standard AS1158 for this type of site. Please run the photometry in DiaLux; Relux or AGi32 is perfectly fine if you prefer, as long as the final values and documentation are traceable to the software’s native calculation files. What I will call complete: • A clear plan view showing lighting positions, aiming angles and mounting heights • Isolux contours or false-colour lux plot demonstrating compliance with the specified AS1158 category • A luminaire schedule with part numbers, lamp data and power consumption • The software project file so I can audit the inputs If anything in the standard looks borderline once you model it, let me know early so we can adjust fittings or positions before you lock in the report.
Projektin tunnus (ID): 40224061
13 ehdotukset
Etäprojekti
Aktiivinen 28 päivää sitten
Aseta budjettisi ja aikataulu
Saa maksu työstäsi
Kuvaile ehdotustasi
Rekisteröinti ja töihin tarjoaminen on ilmaista

With my extensive background in Electrical Engineering, I can confidently address the demands of your AS1158 Outdoor Lighting Design project. My skill set effortlessly transitions to creating compliant lighting layouts for utility areas limited to 100 m² or otherwise, ensuring the necessary safety conditions are met. One key aspect you mentioned is traceability - rest assured I am well-versed with DiaLux, Relux and AGi32, not solely for creating your desired photometry but also for delivering well-documented final values consistent with the software’s native calculation files. Moreover, I understand the importance of effective communication throughout project engagements. Considering this, I ensure a crystal-clear plan view in my outputs including detailed lighting positions, aiming angles and mounting heights. To assure you meet Australian Standard AS1158, I generate isolux contours or false-colour lux plottings alongside a luminaire schedule with part numbers, lamp data and power consumption - everything you need for comprehensive [login to view URL] my extensive background in Electrical Engineering, I can confidently address the demands of your AS1158 Outdoor Lighting Design project.
$200 AUD 7 päivässä
0,0
0,0
13 freelancerit tarjoavat keskimäärin $211 AUD tätä projektia

I am a professional lighting designer with over 15 years of experience in the industry. I specialize in creating effective and aesthetically pleasing lighting solutions for a wide range of spaces—from residential apartments to large-scale projects such as sports fields and warehouses. I have extensive expertise in lighting calculation software, including DIALux Evo, Dialux 4.13, RELUX, and AGi32, allowing me to provide accurate and efficient lighting designs tailored to each project's specific needs. I am ready to perform any lighting calculations to ensure the optimal balance of functionality, efficiency, and visual appeal in your space. Whether you need precise lighting design for an interior, outdoor area, or industrial facility, I can help you achieve the best results.
$250 AUD 5 päivässä
4,6
4,6

Hi, I’m an electrical lighting designer with hands-on experience in DiaLux for safety-driven lighting layouts. I regularly produce AS-compliant photometric studies, including isolux plots, mounting details, and luminaire schedules. I saw your attachment. I can model the area accurately, verify compliance with AS1158, and deliver clear drawings, reports, and the native DiaLux project file for full traceability. Let me know. Thanks.
$150 AUD 7 päivässä
4,6
4,6

Dear Hiring Manager, Greetings. I am a professional Electrical engineer and a Dialux EVO expert. I have read your job description and want to let you know that I can give you a solution by performing lighting calculations on Dialux EVO. Please have a look at my portfolio for my previous project experiences. You are requested to consider me for this project. I assure you that you will get quality work according to your requirements. If you have any question, you can discuss with me any time. Many Thanks. Kind Regards, Haris.
$200 AUD 2 päivässä
4,3
4,3

As an electrical engineer and lighting designer, I have comprehensive knowledge of the Australian Standard AS1158 and the practical skills in using DiaLux, Relux, and AGi32 for photometric calculations. My experience of over 8 years as a 3D Designer, Animator, and CAD expert adds value to the project giving you traceable native calculation files for your future audits. During my career, I’ve always aimed for excellence by meticulously ensuring that all details are in compliance with project specifications. For your AS1158 Outdoor Lighting Design project, this means that not only will I provide a thorough and accurate lighting layout but also valuable insights on any borderline issues that may arise during modelling process. With this approach, we can quickly adjust fittings or positions before finalizing the report. With my availability and commitment to ensure 100% customer satisfaction, you can trust me to get things done on time while exceeding your expectations. Let's transform your vision into reality through excellent communication and fascinating visualizations created with tools such as AutoCAD, SolidWorks, SketchUp and more. Your project is as important to me as it is to you; let’s work together to create something amazing!
$122 AUD 2 päivässä
3,5
3,5

Hi, I can provide a fully compliant lighting layout for your utility area that strictly adheres to Australian Standard AS1158. I will perform the photometry using DIALux to ensure all mounting positions and aiming angles meet the safety requirements for night access. You will receive a comprehensive report including plan views, false color lux plots, and a detailed luminaire schedule with all necessary technical data. I will also provide the native software project file for your audit and transparency. If any calculations appear borderline during the modeling phase, I will alert you immediately to discuss adjustments. My focus is on delivering a precise and traceable documentation package that ensures worker safety. Best regards
$800 AUD 7 päivässä
0,4
0,4

Hi there, I’m excited to offer my expertise in creating a compliant lighting layout for your utility area under 100 m², ensuring all safety standards are met according to AS1158. With extensive experience in lighting design using DiaLux and Relux, I can run thorough photometric calculations, providing clear documentation and supporting files. I’ll deliver a comprehensive plan view that outlines lighting positions, aiming angles, and mounting heights, along with isolux contours demonstrating compliance. My previous projects align seamlessly with your requirements, ensuring safety and functionality are prioritized. Should any aspects of the standard appear borderline during modeling, I will communicate promptly to adjust fittings or positions accordingly. What specific luminaire types or brands do you have in mind for this project?
$70 AUD 2 päivässä
0,0
0,0

AS1158 Outdoor Lighting Design Dear Client. How are you doing? As I'm a Embedded/Firmware Engineer, I have more than 7 years of experience in this field. I'm really interested in your project and I did similar project before several times. Let's discuss your project in more detail. Best regards Rocio
$30 AUD 4 päivässä
0,0
0,0

Hello, I’d be happy to assist with your AS1158-compliant lighting layout. I’m experienced in performing outdoor and utility-area lighting calculations using DiaLux and AGi32, with full documentation traceable to the native calculation files. I understand the importance of meeting the correct AS1158 lighting category to ensure worker safety, including minimum illuminance, uniformity, and mounting requirements. I will provide a clear plan showing luminaire locations, mounting heights, and aiming angles, along with isolux/false-colour plots, a detailed luminaire schedule, and the complete software project file for your audit. If any compliance parameters appear borderline during modelling, I’ll flag them immediately so we can adjust fittings or layout before finalizing the report. I look forward to working with you.
$250 AUD 3 päivässä
0,0
0,0

Dear Client, I have a numerous experience in Lighting and am aware of Australian Standard AS1158. I promise to deliver you project in time. I actaully use dialux Evo. If availed the opportunity, I will be available for this discussion . Regards Johnmary
$140 AUD 7 päivässä
0,0
0,0

Hi, I can provide a complete lighting design solution for your small utility area (<100 m²), ensuring full compliance with Australian Standard AS 1158. The project will focus on providing safe, reliable night-time illumination for worker access. Deliverables include: A clear plan view showing luminaire positions, aiming angles, and mounting heights IsoLux contours or false-colour lux plots demonstrating compliance with the specified AS 1158 category A detailed luminaire schedule with part numbers, lamp specifications, and power consumption The native software project file (DIALux, Relux, or AGi32) for full auditability of all inputs Throughout the project, I will review any borderline areas in the standard and provide recommendations for fitting or placement adjustments to ensure complete compliance. I can start immediately and provide a fully documented, traceable lighting design ready for implementation.
$140 AUD 7 päivässä
0,0
0,0

Hi Dear Sir I specialize in Dialux Evo can help you with Develop project with Your requirements. Post-Delivery Support: 7 days of technical support for troubleshooting after delivery. For a project like yours, I estimate approximately 10 days I'd be happy to discuss details and provide a More precisely quote However Investment (Project Fee) can be: Total Project Fee: 150 AUD Payment Terms: 50% upfront upon project agreement. 50% upon final delivery and your approval.
$150 AUD 10 päivässä
0,0
0,0

Broome, Australia
Maksutapa vahvistettu
Liittynyt heinäk. 31, 2019
$100 USD
₹600-1500 INR
$30-250 USD
₹600-1500 INR
$30-250 USD
₹400-750 INR/ tunnissa
$250-750 USD
₹1500-12500 INR
$250-750 AUD
$250-750 USD
₹1500-12500 INR
₹37500-75000 INR
₹1500-12500 INR
₹12500-37500 INR
₹1500-12500 INR
€8-30 EUR
₹1500-12500 INR
$250-750 USD
$750-1500 USD
₹1500-12500 INR
₹37500-75000 INR