In Progress
Posted
Paid on delivery
1. Comprehensive Structural Calculation Sheet: Wind load calculations in accordance with the Saudi Building Code (SBC 301) for Riyadh, including the Effective Projected Area (EPA) for all top-mounted equipment (CCTV cameras, radio units, and solar modules). Overturning moment calculations and stress checks (Bending, Axial, and Shear) for the 12-meter steel pole ( diameter thickness). Structural design calculations for the base plate and anchor bolts. Complete foundation stability checks (overturning, sliding, and soil bearing capacity) for the concrete foundation. Global Stiffness & Serviceability Check: Detailed verification of the pole's lateral displacement (Tip Deflection) under design wind loads, ensuring it complies with operational serviceability limits required for sensitive PTZ cameras (typically restricted to or higher stiffness) to prevent image blurring or vibration fatigue. 2. Drawing Discrepancy Resolution: There is a direct contradiction in the anchor bolt specifications between the pole detail drawing, which specifies M25 bolts, and the foundation drawing, which specifies M30 grade 8.8 bolts. Please harmonize and revise the drawings accordingly. 3. Geotechnical Report: Provide the approved soil investigation report for the project site in Riyadh to verify the allowable soil bearing capacity. 4. Shop & Fabrication Details: Detailed shop drawings showing the welding specifications between the pole and the base plate, stiffener plate dimensions, and structural detailing around the internal battery access door (including collar/doubler plate details to prevent stress concentration). 5. Material & Protection Specifications: Specification of the steel grade used for the pole and bolts. Hot-dip galvanizing specifications (thickness and standards) for corrosion protection. Confirmation of concrete compressive strength ( at 28 days) and non-shrink grout specifications beneath the base plate. 6. Structural Analysis Model (If available): Kindly share the software analysis model (e.g., SAP2000) if applicable, to expedite our verification process.
Project ID: 40660135
20 proposals
Remote project
Active 5 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs

Hello, I am a Strucutral engineer with 10+ years experience, I am expert in Structural analysis and designs of different structures so i can do the required design drawings and calculations in the required time. I have finished similar projects before and finished 600+ projects. Please check my portfolio and reviews. Thanks.
$50 USD in 3 days
8.7
8.7
20 freelancers are bidding on average $261 USD for this job

As an experienced civil engineer specializing in structural design and analysis, I feel confident in my ability to deliver above and beyond your expectations for the Saudi Project. My expertise in calculating wind loads in accordance with global standards, conducting structural stress checks, and ensuring foundation stability will prove invaluable for aligning your project with Saudi Building Code regulations. I understand the complexities of overlooked details and discrepancies in drawings, such as the anchor bolt specification conflict you've mentioned. I assure you that I'm detail-oriented. My passion for perfection compelled me to always verify drawings, revise where necessary, and provide harmonized solutions before they become problematic. My software proficiency includes AutoCAD and SAP2000 among others which brings effectiveness, accuracy and expedience during the verification process you've demanded. Rest assured, I'll always keep you updated on every stage of your project, making sure it meets your strictest satisfaction. With me on board, not only will you get exceptional structural calculations but also the key peace of mind knowing that everything is being taken care of in a timely and professional manner.
$120 USD in 2 days
7.3
7.3

I read your project details. I'm very much interested to do this project. I'm already experience in it. You can check my previous works at my portfolio section. Please provide some drawings for better understanding. Please message me for further discussion. I'll provide some of my previous work sample. I'll deliver required Design file according relevant code and detailed drawing file. You will get complete structural solution of following civil structures: 1. RCC Structures (Residential, Commercial, Industrial) 2. Steel Structures (Shed, Multistoried Mezzanine, Silo etc.) 3. Tower (Transmission, Telecommunication) 4. Poles (Steel, SPC) 5. Bridges (Steel, RCC, Composite) 6. Composite Structures (Residential, Commercial, Industrial) 7. Foundation (Single, Combined, Mat, Pile, SPC, Screw etc.) We work with the following Analysis, Drawing and Modeling software: 1. Staad Pro. 2. Etabs 3. MS Tower 4. Auto CAD 5. RAM Connection 6. SketchUp 7. Tekla 8. Revit 9. Robot 10. Advance Steel 11. ASDIP Foundation 12. SAP 13. Tekla Tedds 14. GRASP 15. Staad Foundation 16. CSI Detailing 17. MIDAS Civil
$110 USD in 3 days
6.2
6.2

Hey, You are looking for Structural Calculations & Drawings for Saudi Project. "Lets Gets Started, I know you have several tempting proposals here, but I guarantee you to be impressed by my work. I have various skills in design, Illustration, Photoshop, Graphic Design, Logo Design and Illustrator. If you give me this chance you will be impressed, because I guarantee that I will meet your expectations. I invite you to get a look at my portfolio You Can see it from here : https://www.freelancer.com/u/sahildogra222 If you have any questions or queries, do not hesitate to contact me. I hope to start working with you. With regards! SAHIL
$30 USD in 1 day
5.8
5.8

With over a decade of experience as an Architect/Civil/Structural Engineer, I have honed my skills to provide robust, detailed, and high-quality services. Your project in Riyadh requiring wind load calculations under the Saudi Building Code is right up my alley. I am deeply familiar with structural design considerations for equipment like CCTV cameras, radio units, and solar modules atop poles - such as the 12-meter steel pole you specified - including EPA assessment and overturning moment calculations. Furthermore, my prior audits of site plans for foundation stability checks and soil bearing capacity studies align perfectly with your fourth requirement. Finally, proficiency in using AutoCAD and familiarity with analysis softwares like SAP2000 fortify my case. These tools enable me to perform task-specific calculations effectively thereby streamlining overall project delivery time. I understand the significance of your project's objectives and am excited about meeting them with preciseness, diligence, and professionalism. Let's collaborate to bring this vision to reality!
$2,000 USD in 7 days
5.7
5.7

Hello, I am a Structural Engineer with strong experience in steel pole/tower design, wind-load analysis, foundation and anchor-bolt design, and preparation of detailed structural/shop drawings. I can handle this Riyadh project from engineering calculations through drawing reconciliation and fabrication detailing. For your 12-meter steel pole, I will develop a complete structural verification package based on the Saudi Building Code (SBC 301) and applicable international structural standards, including: - Wind-load calculations for Riyadh, including EPA calculations for CCTV/PTZ cameras, radio equipment, solar modules, and other top-mounted components. - Global structural analysis of the pole for bending, axial force, shear, overturning moment, member stresses, and load combinations. - Serviceability/stiffness verification, including pole top deflection under wind loading, with particular attention to the stringent operational requirements of PTZ cameras to minimize image movement and vibration. - Complete base plate and anchor-bolt design, including verification of bolt tension, shear, combined actions, base-plate bending, and connection adequacy. - Foundation stability checks for overturning, sliding, soil bearing pressure, and resultant/eccentricity. - Resolution of the M25 vs M30 Grade 8.8 anchor-bolt discrepancy, with a technically coordinated recommendation and corresponding drawing revisions. - Detailed shop/fabrication drawings, including weld details, stiffener plates, base-plate connection, and reinforcement/collar/doubler details around the battery access door to control local stress concentrations. - Review and specification of steel grade, bolt grade, hot-dip galvanizing requirements, concrete strength, and non-shrink grout. - Coordination of the structural calculations with the available SAP2000/STAAD or equivalent analysis model, where provided. - Review of the geotechnical information and verification of the adopted allowable soil bearing capacity; I will clearly identify any geotechnical data that must be supplied or officially approved by the project team rather than assuming unsupported soil parameters. My approach will be to first establish the governing design loads and equipment projections, then perform the pole/connection/foundation checks as one integrated load path. This ensures that the pole, base plate, anchor bolts, and concrete foundation are all designed consistently rather than checked independently. I can work directly from your existing DWG/PDF drawings and return a coordinated calculation package and revised fabrication-ready drawings with clear engineering assumptions, governing cases, and design results. I am available to start immediately and can prioritize this as an urgent engineering review. Best regards, Structural Engineering Specialist
$90 USD in 6 days
5.0
5.0

With 5+ years of experience in structural design, steel structures, foundation design, and engineering documentation, I can assist with preparing and reviewing the complete structural calculation and fabrication package for your 12-eter steel pole in Riyadh. My scope can include Wind load and EPA calculations in accordance with SBC 301, including CCTV/PTZ cameras, radio equipment, solar modules, and all top-mounted accessories. Pole structural checks for bending, axial load, shear, combined stresses, and stability. Detailed tip-deflection/serviceability verification, considering the operational requirements of sensitive PTZ cameras and vibration concerns. Base plate, stiffener, and anchor-bolt design, including harmonizing the M25/M30 discrepancy based on the governing structural calculations. Concrete foundation checks for overturning, sliding, soil bearing pressure, and stability. Detailed shop/fabrication drawings, including pole-to-base-plate welds, stiffener dimensions, battery access-door reinforcement, and collar/doubler plate detailing. Material specifications for steel, bolts, concrete, non-shrink grout, and hot-dip galvanizing. Structural analysis using SAP2000 or equivalent, with the analysis model provided where applicable. I’m ready to revie the existing pole and foundation drawings and identify the missing dimensions, pole diameter/thickness, equipment weights/EPA, camera serviceability criteria, and soil parameters needed to finalize the design.
$40 USD in 2 days
4.0
4.0

I can assist with the structural verification and documentation of your 12-meter steel pole installation in Riyadh. I understand that the priority is a complete engineering review covering wind loading, pole strength, base connection, foundation stability, and serviceability, while also resolving the discrepancies in the existing drawings. Scope of Work Wind load calculations in accordance with SBC 301 for Riyadh. Effective Projected Area (EPA) calculations for CCTV, radio equipment, and solar modules. Pole checks for bending, axial force, shear, and overturning moment. Lateral displacement/tip deflection and global stiffness verification for PTZ camera serviceability. Base plate, stiffener, and anchor-bolt design/checks. Foundation checks for overturning, sliding, and soil bearing. Reconciliation of the M25 vs. M30 Grade 8.8 anchor-bolt discrepancy. Review of steel, concrete, grout, welding, and hot-dip galvanizing specifications. Shop/fabrication detailing around the base plate and battery access opening. Review of the geotechnical information and allowable soil bearing capacity provided by the project team. Review of an existing SAP2000/other analysis model if available. Deliverables Comprehensive structural calculation package. Revised/coordinated structural drawings and connection details. Anchor-bolt and foundation verification.
$30 USD in 2 days
2.2
2.2

The project faces a key risk with the contrasting anchor bolt specifications. If we don’t resolve the discrepancy between the M25 bolts and the M30 grade 8.8 bolts, we could end up with structural failure or costly rework. This could delay timelines and inflate costs significantly. I'd start by harmonizing the drawings to ensure consistency. This way, we align the structural integrity with the design requirements right from the get-go. I’ll also conduct thorough wind load calculations per SBC 301, ensuring compliance for the sensitive PTZ cameras. I’ve tackled similar projects, always including revisions in my process to enhance accuracy and detail. I know how vital it is to get these specifics right. What’s your timeline for this project? Do you have the approved soil investigation report ready?
$100 USD in 7 days
2.0
2.0

Hi , You need an expert in AutoCAD, Civil Engineering, Geotechnical Engineering, Structural Engineering, Mechanical Engineering, Shop Drawings and Project Management, and I have a tailor-made solution ready for you. Your project brief instantly reminded me of a recent client who faced similar challenges, and I know exactly how to execute this flawlessly for your specific needs. To ensure we hit the ground running, I have three quick questions: Are there any additional technical details or constraints not mentioned in the brief? What is the primary hurdle currently blocking your progress on this? What is your strict timeline for completion? Why trust me with your project? The Record: 250+ Projects. 6+ Years. 100+ consecutive 5-star reviews. The Standard: Zero misses. I don’t just finish the job; I guarantee flawless execution. The Availability: Full-time freelancer, online 9 AM - 9 PM EST. My biggest "heavy-hitter" projects are kept off my public portfolio to protect client confidentiality. Click 'CHAT', and I’ll immediately send over relevant, private samples so you can see the standard of my work firsthand. Best regards, Muhammad Arsalan
$30 USD in 6 days
0.0
0.0

Hello, As a full-stack developer and creative design expert with over 16 years in the industry, I can say without hesitation that my expertise extends not only to web and mobile development but also to areas like your structural calculations and drawings. My understanding of AutoCAD would be particularly instrumental here as I will diligently work on resolving the directive conflict in anchor bolt specifications, map out draw steeped in serviceability checks, and establish how soil bearing capacity affects your project site. The collective experience of my team, which consists of 55+ skilled professionals, reflects our determination to take on any project irrespective of its size. Moreover, since I have dedicated a substantial amount of time refining my skills with applications like Autodesk Maya, Blender and Autodesk 3ds Max, you can rest assured knowing that your project is in the hands of someone who has significant exposure to intricate and complex details. Lastly, transparency and communication are at the core of how I function. I believe that trust is cemented with client satisfaction. So you can expect a clear line of communication as well as high-quality work that not only adheres to your requirements but more importantly adds value to your project! Thanks!
$155 USD in 1 day
0.0
0.0

Hello, I can prepare the full structural calculation package and coordinated drawings for your Saudi project in Riyadh, including SBC 301 wind loads, EPA for all mounted equipment, overturning and stress checks for the 12 m pole, base plate and anchor design, foundation stability, and tip-deflection/serviceability verification for PTZ camera performance. I will also resolve the M25 vs M30 anchor discrepancy, align the pole and foundation details, and provide fabrication-ready shop details for welding, stiffeners, and the battery access door reinforcement. I can incorporate the steel, galvanizing, grout, and concrete specification notes directly into the deliverables and format the package for straightforward review. Best regards, Panagiotis
$155 USD in 2 days
0.0
0.0

Hello, I can provide the full structural calculation package for your 12 m steel pole in Riyadh, including SBC 301 wind load and EPA checks, overturning and combined stress verification, base plate and anchor bolt design, and foundation stability checks for overturning, sliding, and bearing. I’ll also verify tip deflection and global stiffness to protect PTZ camera performance under design wind. I will resolve the anchor bolt discrepancy between the pole and foundation drawings, specify steel grades, bolt grades, hot-dip galvanizing, concrete strength, and grout requirements, and provide clear shop/fabrication details for welds, stiffeners, and the battery access door. A geotechnical report can be coordinated if needed, and I can share or rebuild the SAP2000 model to support your verification. Best, Serhii
$140 USD in 7 days
0.0
0.0

I am a Mechanical Engineer with extensive experience in structural analysis, steel structure design, 3D CAD modeling, and engineering documentation. My experience is primarily focused on steel structures and steel construction, rather than reinforced concrete projects. I have designed and analyzed a wide range of industrial and structural systems, including a 15 × 8 m two-storey steel office building, industrial steel structures, lifting structures, machinery support frames, roofs, and heavy mechanical structures. My previous work includes the structural design and FEA of a 32-ton nuclear reactor door, including static and seismic loading; a 31-ton Şişecam glass lifting beam, for which I performed both manual calculations and FEA as part of the CE certification process; and the structural design and analysis of a 100 t/h coal washing plant and its associated steel structures. I use SAP2000, ANSYS, SolidWorks Simulation, SolidWorks, AutoCAD structural analysis, 3D modeling and fabrication documentation. I can prepare detailed 3D models, manufacturing drawings, load calculations and structural analysis reports. I can perform the analysis in SAP2000 and prepare the drawings in AutoCAD for this project. Do you have a simple drawing or sketch available?
$1,200 USD in 15 days
0.0
0.0

Riyadh, Saudi Arabia
Payment method verified
Member since Aug 20, 2026
$30-250 USD
$250-750 USD
$30-250 USD
$15-25 USD / hour
min $50 USD / hour
$750-1500 USD
₹1500-12500 INR
₹7500-9000 INR
₹2000-4500 INR
$250-750 USD
₹12500-37500 INR
$30-250 USD
₹1500-12500 INR
₹12500-37500 INR
£10-15 GBP / hour
£20-250 GBP
₹600-1500 INR
₹250000-500000 INR
min $50 USD / hour
$15-25 AUD / hour