I need a formal calculation package prepared in full compliance with NFPA 72 Chapter 7 so I can file it alongside the as-built documentation for our fire-alarm upgrade. The system centres on a hybrid fire-alarm control panel; at this stage only the panel data are locked in, with initiating and notification circuits still being finalised. Once you are aboard I will forward the panel cut-sheets, device counts and wiring topology. Your task is to generate three items and place them into a clear, engineer-ready PDF: • Battery sizing calculations that prove the panel will operate through its required standby and alarm periods (backup duration is open—show your working so we can adjust easily). • Maximum allowable circuit / loop / network lengths based on the panel’s published current limits and conductor gauges. • End-to-end voltage-drop calculations for each circuit, referenced to the worst-case load. Each worksheet must reference the specific NFPA 72 clauses you apply, include formulas (not just final numbers), and cite all manufacturer data sheets you use. I will review the draft against our jurisdiction’s submittal checklist; once everything balances, I’ll need both an editable spreadsheet and the signed PDF. If you regularly work in tools such as Excel, AutoCAD Electrical, or specialised FAS calculation software, mention it so I can align the file formats.
Project ID: 40671033
32 proposals
Remote project
Active 2 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
32 freelancers are bidding on average $21 USD/hour for this job

I am a Professional Fire Protection Engineer with extensive experience designing code-compliant fire alarm for commercial and residential projects. I have exceptional experience using AlarmCAD & AutoCAD, and I have completed over 50 fire protection design projects. I can design your Fire alarms systems, based on the architectural drawings while ensuring compliance with your requirements, applicable NFPA standards, and local codes. I pay close attention to detail, communicate throughout the project, and deliver accurate, buildable drawings on schedule. Let's discuss your project scope and requirements. I look forward to working with you. Thank you.
$20 USD in 40 days
6.9
6.9

Dear Sir, Please contact me to get started. Thanks. I am an Electrical Design Engineer having 15+ years of experience in Design of Electrical System for Residential and Commercial low/high rise buildings. I will provide all aspects of Electrical System for your project as per standards (NEC or any local if any) and specification within the required time and budget. I will also share my previous samples. Well versed in; 1. Lighting Layouts 2. Power Layouts 3. Single Line Diagram 4. Fire Alarm System 5. ELV (Subject to Client’s requirement) 6. Lighting Protection System 7. Design Calculations 8. Equipment Installation Detail Drawings. 9. Take-off sheets and Bills of quantity 10. Technical Specifications and more.
$25 USD in 40 days
6.3
6.3

Hello, I am Muhammad Javed, an electrical engineer with more than 10 years of experience in fire alarm systems, electrical design, load calculations, and engineering documentation. I can prepare a complete, engineer-ready calculation package for your hybrid fire-alarm control panel, including battery sizing, maximum allowable circuit/loop/network lengths, and end-to-end voltage-drop calculations. Once you provide the panel cut-sheets, device quantities, wiring topology, and conductor details, I will build the calculations around the actual system configuration and worst-case loading. Each worksheet will clearly show the applicable formulas, assumptions, intermediate calculations, and final results rather than providing numbers alone. I will reference the relevant NFPA 72 Chapter 7 requirements and manufacturer datasheet information used for the calculations, making the package straightforward to review and update when circuit details change. I can prepare the calculations in Excel with an editable structure so standby/alarm durations, device counts, conductor gauges, and loads can be adjusted easily. The finalized package can then be formatted into a professional PDF suitable for inclusion with your as-built documentation. I will also review the completed calculations for consistency between battery capacity, circuit loading, conductor sizing, and voltage-drop limits before final delivery.
$20 USD in 40 days
6.2
6.2

Hi, I am ready to assist you with a complete NFPA 72 fire alarm calculation package, including battery sizing, maximum circuit lengths, and voltage-drop calculations, with all formulas and code references, following NFPA 72 Chapter 7 standards for an accurate, engineer-ready submittal. Project Deliverables: Battery sizing calculations Maximum allowable circuit/loop/network lengths End-to-end voltage-drop calculations for each circuit Editable spreadsheet and signed PDF I have a few questions: Q1: Could you share the panel cut-sheets, device counts, and wiring topology to begin the calculations? Q2: Do you have any specific backup duration or battery type preferences for sizing? Over 7 years of experience in electrical engineering, fire alarm design, and NFPA 72 compliance calculations. Similar projects I have done: NFPA 72 Fire Alarm Calculation Package for Commercial Building Battery Sizing and Voltage-Drop Calculations for Fire Alarm Systems Software I can use: Excel AutoCAD Electrical My portfolio is attached below. I am ready to start immediately and look forward to receiving your panel data and device counts. Thank you! Warm regards, Abubakar
$20 USD in 40 days
5.1
5.1

Hello sir سلام عليكم I have 11 years of experience as a Senior Electrical Power Systems Engineer leading an electrical and life-safety design team. We specialize in fire alarm system engineering, battery sizing, voltage drop analysis, circuit distance calculations, and preparing submittal packages fully compliant with NFPA 72 (National Fire Alarm and Signaling Code) standards. Technical Summary of Compliance Codes NFPA 72 Chapter 10 & 14 (Power Supplies & Testing): Regulating secondary power supply duration requirements (e.g., 24 hours standby plus 5 minutes alarm for general systems, or 15 minutes for emergency voice evacuation). NFPA 72 Chapter 7 (Documentation): Dictating design documentation rules, calculation formatting, signature verification, and field acceptance test submittals. Deliverables & File Format Alignment Editable Engineering Calculation Spreadsheet: Fully dynamic Microsoft Excel (.xlsx) workbook featuring active formulas, transparent cell references, parameter input cells, and multi-tab organization for battery capacity, loop lengths, and NAC voltage drop. Formal Submittal PDF Package: Scaled, clean, engineer-ready PDF report with cover page, NFPA 72 clause reference table, clear formula steps, and manufacturer cut-sheet cross-references ready for authority having jurisdiction (AHJ) submittal. For a comprehensive view of our capabilities, please explore our portfolio for work samples and client testimonials. Regards, Eslam
$15 USD in 20 days
5.3
5.3

I have 4+ years of experience preparing technical calculation packages and engineering documentation, including Excel-based calculations and electrical/fire-alarm system documentation. For your fire-alarm upgrade, I can prepare the complete calculation package covering: - Battery sizing for the required standby and alarm durations, with adjustable assumptions and full formulas. - Maximum allowable circuit/loop/network lengths based on the panel’s published current limits, conductor resistance, and selected wire gauges. - End-to-end voltage-drop calculations for each initiating/notification circuit using the worst-case device load. - NFPA 72 Chapter 7 clause references throughout the worksheets. - Manufacturer cut-sheet references for all panel and equipment data used. - Clearly documented assumptions so the calculations can be updated easily when the final device counts and topology are provided. - Engineer-ready formatting suitable for review alongside the as-built/submittal documentation. I can provide the calculations in an editable Excel workbook and prepare the finalized PDF package once the design inputs are confirmed. I’m also comfortable working with electrical/FAS documentation and can structure the deliverables so they are straightforward for an engineer to review and sign.
$15 USD in 40 days
4.4
4.4

Hi, I can prepare the NFPA 72 Chapter 7 fire-alarm calculation package for your hybrid fire-alarm control panel upgrade. My approach will be to review the panel cut-sheets, device counts, conductor gauges, circuit topology and manufacturer limits, then build an editable Excel calculation workbook and engineer-ready PDF package. I can help with: * Battery sizing calculations * Standby and alarm load calculations * Circuit / loop / network length checks * Worst-case voltage drop calculations * Device current schedule * Formula-based Excel worksheets * NFPA 72 clause references * Manufacturer datasheet references * Clear technical documentation Deliverables: * Editable Excel calculation file * PDF calculation package * Battery backup worksheet * Circuit length worksheet * Voltage drop worksheet * Assumptions and source references * Draft review support * Final signed PDF if credentials/sign-off requirements are met I’ll focus on clear formulas, traceable manufacturer data, adjustable assumptions, and a clean package suitable for review with your as-built fire-alarm documentation. Best regards Ankit
$15 USD in 40 days
4.2
4.2

Hi, I can help prepare an engineer-ready NFPA 72 Chapter 7 calculation package for your fire alarm upgrade, including battery sizing, circuit length limits, and voltage-drop calculations. I’ll build the worksheets around your panel specifications, device loads, wiring details, and manufacturer data to provide clear, review-ready documentation. I’ll include formulas, calculation steps, NFPA 72 clause references, and manufacturer datasheet citations rather than only final values. I can organize the deliverables into an editable spreadsheet and formatted PDF with calculations structured for submittal review. Question: Do you already have the panel manufacturer cut-sheets and the required jurisdictional submittal checklist available for reference? Best regards
$20 USD in 40 days
3.8
3.8

Hello, I’m a Mechanical Engineer experienced in technical calculations, Excel-based engineering worksheets, and fire protection/MEP documentation. I can prepare the required fire-alarm calculation package with clear formulas and traceable inputs, including battery sizing, circuit/loop length limits, and end-to-end voltage-drop calculations based on the panel data, device loads, conductor sizes, and wiring topology provided. I can structure the worksheets so the standby/alarm durations and other design inputs can be easily adjusted, with manufacturer data and applicable NFPA 72 requirements clearly referenced. I can provide both an editable Excel workbook and a professionally formatted PDF for review and submittal. Once you provide the panel cut-sheets and finalized device/circuit information, I can review the requirements and proceed with the calculations. Best regards, Ahmed
$25 USD in 40 days
4.1
4.1

Hi, I can assist with preparing a clear, engineer-ready fire alarm calculation package based on the panel cut-sheets, device loads, conductor sizes, and final circuit topology you provide. The package can include: * Battery standby/alarm sizing with adjustable assumptions and full formulas * Maximum circuit, loop, and network length calculations * Worst-case voltage-drop calculations for each circuit * References to the applicable NFPA 72 requirements * Manufacturer data-sheet citations and documented design inputs * An editable Excel workbook plus a professionally formatted PDF I’m comfortable working in Excel for structured engineering calculations, including formulas, linked assumptions, validation checks, and clearly organized worksheets so future device-count or backup-duration changes can be updated easily. I can also structure the workbook so each calculation clearly shows inputs, formulas, results, and pass/fail criteria for easier jurisdictional review. One important note: I can prepare the calculation package and documentation, but if the authority having jurisdiction requires a licensed engineer’s signature or professional seal, final signing should be completed by the appropriately licensed engineer of record. I can start as soon as you provide the panel data sheets, device schedule, wiring topology, conductor gauges, and jurisdictional checklist. Best regards, Enrique
$20 USD in 40 days
1.5
1.5

Yes, we can prepare the complete NFPA 72 Chapter 7-based calculation package, including: Battery sizing for standby/alarm duration Maximum circuit/loop lengths Worst-case voltage-drop calculations Applicable NFPA 72 clause references Manufacturer data-sheet references Editable Excel calculation workbook Engineer-ready signed PDF Please share the panel cut-sheets, device counts, cable specifications and wiring topology. We can then proceed with the detailed calculations. We work with Excel and AutoCAD/AutoCAD Electrical for engineering documentation.
$16 USD in 30 days
1.2
1.2

HI, KINDLY READ THROUGH MY PROPOSAL Your panel-first approach makes sense, locking in the hybrid FACP before finalizing circuits lets us size batteries and voltage drop against real current draw, not estimates. I'm a Fire Alarm Systems Engineer with 6 years designing NFPA 72 Ch.7-compliant packages, battery standby/alarm sizing, T-tap/Class A/B loop length limits, and end-to-end voltage drop referenced to worst-case load, all clause-cited with manufacturer data sheets. I work in Excel for editable calc sheets and AutoCAD Electrical for topology, can align formats with your submittal checklist. Quick questions: Panel make/model + battery amp-hour options? Class A or B circuits? Standby/alarm duration required by AHJ? PLEASE INITIATE A CHAT I look forward to collaborating with you on this project.
$15 USD in 40 days
0.6
0.6

Hi, I can prepare a clear and engineer-ready NFPA 72 fire alarm calculation package covering battery sizing, maximum circuit/loop/network lengths, and end-to-end voltage-drop calculations. I have an engineering background with practical experience in electrical calculations, Excel-based engineering documentation, MATLAB/Simulink and power-electronics systems, and I am comfortable working from panel cut-sheets, device counts, wiring topology and manufacturer datasheets. I will provide the formulas, assumptions, worst-case load calculations and applicable NFPA 72 references, with the calculations organised in an editable Excel workbook and professional PDF for your review. I can also structure the worksheets so standby/alarm durations and other parameters can be adjusted easily when your final circuit details are provided.
$20 USD in 30 days
0.8
0.8

Hello, As an experienced IT professional for over 16 years, specializing in technical writing, my skillset aligns perfectly with your project requirements. While my expertise may not lie in NFPA 72 calculations specifically, I am highly efficient when it comes to working on complex engineering projects and delivering output with immaculate precision, which is exactly what your project demands. Understanding the importance of compliance, I'm committed to delivering a calculation package that strictly adheres to NFPA 72 guidelines. Whilst I am not an expert in specialised FAS software, my excellent command over tools like Excel and AutoCAD Electrical enables me to provide quality outputs in a variety of formats - something that will come in handy for your file requirement. Thanks!
$20 USD in 1 day
0.0
0.0

Hi there, I have experience preparing fire-alarm engineering calculation packages covering battery capacity, circuit loading, voltage drop, conductor sizing, and manufacturer-specific equipment data for permit and as-built documentation. I will build the calculation package around the selected hybrid fire-alarm panel, using the panel cut-sheets, device counts, wiring topology, conductor gauges, and finalized circuit data to calculate required standby/alarm battery capacity, maximum circuit/loop/network lengths, and worst-case end-to-end voltage drop. I will document every calculation with formulas, assumptions, applicable NFPA 72 Chapter 7 references, manufacturer data-sheet citations, and adjustable inputs so standby/alarm durations or device quantities can be updated without rebuilding the worksheets. I will deliver an engineer-ready PDF plus an editable calculation spreadsheet, with the final signed/sealed PDF subject to review and execution by the appropriately licensed professional required by your jurisdiction. Let's get started. Thank you, Kinetik
$20 USD in 40 days
0.0
0.0

I understand the critical importance of delivering a compliant calculation package for your NFPA 72 fire alarm upgrade. With extensive experience in preparing formal calculation documents, I can transform your panel data into a polished, engineer-ready PDF that meets all specified requirements. I will create detailed worksheets for battery sizing calculations, maximum allowable circuit lengths, and end-to-end voltage-drop calculations, ensuring each references the relevant NFPA 72 clauses and includes all necessary manufacturer data. My attention to detail guarantees that you will have a clear and accurate submission ready for your jurisdiction. I regularly utilize Excel for calculations and can also work with AutoCAD Electrical if needed. Once we finalize the calculations, I will provide both an editable spreadsheet and the signed PDF for your records. Let’s discuss how we can move forward with this essential project. Kind regards, Anchel
$15 USD in 7 days
0.0
0.0

Hello, The key challenge is producing calculation sheets that are transparent, adjustable, and properly tied to the specific fire-alarm panel data, circuit topology, conductor sizes, and worst-case loads rather than simply presenting final values. I’d prepare the battery sizing, maximum circuit/loop/network length, and end-to-end voltage-drop calculations in Excel, with formulas and clear assumptions throughout. I’d reference the applicable NFPA 72 requirements and manufacturer cut-sheet data, then compile the calculations into an engineer-ready PDF alongside the editable spreadsheet. Please send the panel cut-sheets, device counts, wiring topology, conductor gauges/lengths, and jurisdictional submittal requirements so I can build the calculations around the actual system
$15 USD in 40 days
0.0
0.0

Battery sizing, voltage drop and circuit-length limits are routine work for me - 12 years in electrical distribution and building services, including testing and commissioning of fire alarm systems. Up front: I can sign as the engineer who prepared and checked the calculations, but not provide a licensed seal. If your submittal needs one that stays with your licence holder - the package is built so they can verify and seal it quickly. Panel data is locked, circuits aren't, so I'd split it. Phase 1 now: standby and alarm battery calculation from your cut-sheets, as a live spreadsheet - load table, quiescent and alarm currents, derating and ageing factors and standby duration all editable, so it survives the circuits changing. Phase 2 once circuits are fixed: maximum loop and NAC lengths against published current limits and conductor gauges, and end-to-end voltage drop per circuit at worst case. Format: Excel. Live workbook with every formula visible in-cell, no hard-coded results, plus the engineer-ready PDF. Each sheet is laid out to your Chapter 7 documentation requirements, and carries the clause applied, the formula as written, and a citation to the data sheet and page each figure came from. One ask: send me your jurisdiction's submittal checklist at the start rather than at review. Formatting the worksheets to it once is cheaper for both of us than reworking after your check.
$20 USD in 10 days
0.0
0.0

Hello, I can prepare an engineer-ready NFPA 72 calculation package covering battery sizing, maximum circuit/loop lengths, and worst-case voltage drop. I am an Electrical Engineer with over 13 years of experience, including NFPA 72 fire-alarm work for Abu Dhabi Airport and industrial projects. Once you provide the information needed, I can produce the workbook and submission-ready PDF. Kind regards, Vehbi
$22 USD in 20 days
0.0
0.0

Dammam, Saudi Arabia
Payment method verified
Member since Aug 25, 2026
$8-10 USD / hour
₹1500-12500 INR
$1500-3000 USD
₹12500-37500 INR
£20-250 GBP
$250-750 USD
$15-25 USD / hour
$30-250 USD
₹1500-12500 INR
$10-30 USD
$750-1500 USD
€200-400 EUR
$5000-10000 USD
$250-750 USD
₹600-1500 INR
₹1500-12500 INR
$3000-5000 USD
$1500-3000 USD
₹1500-12500 INR
$250-750 AUD