I am fitting-out a new 600 m² commercial gym and need a certified electrical engineer to turn my concept layout into a complete, code-compliant design package. The scope centres on two areas: • Lighting – I have a current layout design to use and need to include, gym, rooms and fight gym, reception and back-of-house, plus fully detailed emergency lighting coverage with photometric calculations. • Power distribution – A standard commercial board is fine; no specialised high-load machinery is planned. The design should simply balance normal gym equipment, HVAC connection points and general socket circuits while providing room for future expansion. Please prepare drawings and schedules in AutoCAD or Revit (whichever you prefer) and use Dialux/Relux or similar for lighting calculations. All work must align with local electrical codes and any relevant IEC/AS/NFPA sections. Deliverables I need from you: • Single-line diagrams and load calculations • Lighting layout with lux plots and emergency overlay • Circuit schedules and panel board schedules • Cable sizing, containment routing and breaker selection • A brief design report summarising assumptions and compliance references I will provide the architectural plan in DWG as soon as we start. Let me know your estimated turnaround and any information you still need.
Project ID: 40709370
17 proposals
Remote project
Active 5 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs

I’m an Electrical Engineer with 6+ years of experience in commercial electrical design, lighting layouts, load calculations, power distribution, AutoCAD/Revit documentation, and electrical coordination. I can develop the complete electrical design package for your 600 m² commercial gym, including: • Lighting layouts for gym areas, rooms, fight gym, reception and back-of-house • Emergency lighting layout with lux/photometric calculations using DIALux/Relux • Single-line diagram and load calculations • Panel schedules, circuit schedules and load balancing • Cable sizing, breaker selection and containment routing • HVAC, gym equipment and general socket circuits with allowance for future expansion • AutoCAD/Revit drawings and a concise design/compliance report • Coordination with the supplied architectural DWG I’ll base the design on the applicable local electrical requirements and relevant IEC/NFPA provisions, with clear assumptions and calculation documentation. I can start as soon as you provide the architectural DWG, lighting concept, supply details and project location/code jurisdiction. Estimated turnaround is 5–7 days depending on the completeness of the inputs. If local regulations require a licensed/certified engineer’s final approval or seal, I can prepare the complete technical package for review and sign-off by the appropriately licensed professional.
$250 AUD in 5 days
0.0
0.0
17 freelancers are bidding on average $439 AUD for this job

Hello, my name is Fuly Peña. We are a multidisciplinary team that carries out complete architectural projects, including the electrical components; I can handle your electrical project and ensure it meets all permit requirements. Please take a look at my portfolio and the ratings from previous projects.
$550 AUD in 12 days
4.9
4.9

Hello This is Mohand, Electrical engineer. I can develop your 600 m² commercial gym concept into a coordinated electrical design package covering lighting, emergency lighting, power distribution, calculations, and complete documentation. Scope of Work: ☑️ Develop lighting layouts for the gym, rooms, fight gym, reception, and back-of-house areas ☑️ Perform Dialux/Relux lux and emergency-lighting calculations with clear photometric plots ☑️ Prepare single-line diagrams, load calculations, panel schedules, and circuit schedules ☑️ Complete cable sizing, breaker selection, containment routing, socket circuits, HVAC connections, and future capacity allowance ☑️ Coordinate the electrical design with the architectural DWG and gym equipment layout ☑️ Prepare a concise design report with assumptions and applicable IEC/AS/NFPA/code references ☑️ Deliver organized AutoCAD/Revit drawings, calculation reports, schedules, and PDFs Estimated turnaround: 5–7 business days after receiving the architectural DWG and project/code information. Please provide the architectural DWG, project location, utility/supply voltage, available equipment schedule, HVAC loads, and applicable local electrical code. Where a certified local electrical engineer's professional seal is legally required, final review and certification should be completed by the appropriately licensed professional. Best Regards, Mohand
$500 AUD in 10 days
4.2
4.2

Hello, I can develop the electrical design package for your 600 m² commercial gym based on the architectural DWG and your existing lighting concept. The scope can include lighting and emergency lighting layouts, Dialux/Relux photometric calculations, lux plots, power distribution, load calculations, single-line diagrams, panel and circuit schedules, cable sizing, breaker selection, containment routing, and a concise design report with the applicable code references. I will coordinate the design for the gym areas, fight gym, rooms, reception and back-of-house, while allowing for balanced general power, HVAC connection points and reasonable future expansion capacity. I can prepare the drawings in AutoCAD or Revit and use Dialux/Relux for the lighting calculations. The final design will be developed around the applicable local electrical requirements together with the relevant IEC/NFPA provisions. Please provide the architectural DWG and confirm the project location, supply characteristics (voltage/phase/frequency), and the applicable local authority/code requirements. I can then confirm the final scope and estimated turnaround accurately. Best regards, ENG MOKL
$250 AUD in 7 days
3.0
3.0

Greetings! I can deliver a complete, code-compliant electrical design package for your 600 m² commercial gym. For lighting, I will use your current layout design to cover the gym, rooms, fight gym, reception, and back-of-house, plus fully detailed emergency lighting with photometric calculations in Dialux or Relux. For power distribution, I will design a standard commercial board that balances gym equipment, HVAC connection points, and general socket circuits while leaving room for future expansion. You will receive single-line diagrams and load calculations, lighting layout with lux plots and emergency overlay, circuit and panel board schedules, cable sizing, containment routing, and breaker selection, plus a brief design report summarising assumptions and compliance references. I will work in AutoCAD or Revit and align everything with local electrical codes and relevant IEC, AS, or NFPA sections. Happy to confirm turnaround once I review the architectural DWG. Thanks, Revival
$250 AUD in 7 days
1.5
1.5

This brief forces a technical choice on lighting calculation software, Dialux or Relux. I'd go with Dialux for this project because its interface is more direct for demonstrating photometric results to clients who may not have deep technical backgrounds, so it serves your need for a clear design package. I'll start by translating your concept layout into a Revit model for the electrical design, so I can precisely place all lighting fixtures and power outlets. Then, I'll use Dialux to model the lighting, running photometric calculations to ensure code compliance and optimal coverage for each gym area, reception, and back-of-house spaces, also detailing the emergency lighting. For power distribution, I will design a standard commercial board layout balancing gym equipment, HVAC, and general sockets, including circuits for future expansion. The order of operations will be to first complete the lighting design and calculations in Dialux, so that its power requirements feed directly into the Revit electrical distribution model. You mention needing drawings and schedules in AutoCAD or Revit. I will use Revit for the entire design package, so you get a single, integrated model for both lighting and power. Preferred Freelancer here, 5.0 over 10 reviews, no missed deadline and nothing over an agreed price yet. What is the preferred file format for the final deliverable drawings package beyond the Revit model itself, so I can prepare the exact outputs you need. A short call on Freelancer to settle the scope would cover confirming the specific Revit version for the final deliverable and establishing the preferred output format for all drawing sheets.
$738 AUD in 21 days
0.0
0.0

Hello, I fully understand your needs, as I have previously worked on a project similar to your specifications. I am an experienced architect specializing in 3D design and rendering. I have extensive experience using AutoCAD, SketchUp, and Revit 2027, and I can deliver the required design drawings on time. I would be delighted to work on your project. I have carefully reviewed your project details. If you choose me, your project will be completed quickly and to a high standard. Thank you for your interest.
$250 AUD in 2 days
0.0
0.0

I have similiar project related to 600 m² commercial gym electrical design project. I have 5+ years of experience in electrical engineering, commercial power distribution, AutoCAD/Revit drafting, load calculations, SLDs, panel schedules, cable/breaker sizing, and lighting design. I can develop the complete design package including lighting and emergency lighting layouts, Dialux/Relux photometric calculations and lux plots, SLDs, load calculations, circuit/panel schedules, cable and containment sizing, breaker selection, and a concise design report with applicable IEC/BS/NFPA and local-code references. I’ll coordinate the gym, fight gym, rooms, reception, BOH, HVAC points and general sockets while allowing practical spare capacity for future expansion. Estimated turnaround: 7–10 days after receiving the DWG and project information. Please provide the architectural DWG, incoming supply details, HVAC/equipment loads, and the applicable local authority/code requirements. Final certification/sealing can be completed by the locally licensed engineer where required.
$250 AUD in 5 days
0.0
0.0

Hi there, I'm an experienced Electrical Engineer with over 12 years of expertise in commercial building systems design. Your 600 m² gym fit-out requires a comprehensive electrical solution, and I have extensive experience delivering exactly this type of project. I'll transform your concept layout into a fully code-compliant design package covering: • Detailed lighting design using photometric calculations (Dialux/Relux) with lux plots and emergency coverage overlay for all zones, gym, studios, reception, back-of-house • Complete power distribution strategy balancing gym equipment loads, HVAC connection points, and general circuits with built-in expansion capacity • Full technical documentation: single-line diagrams, load calculations, circuit schedules, panel board schedules, cable sizing, containment routing, and breaker specifications • Compliance design report referencing local codes and relevant IEC/AS/NFPA standards I'll work in AutoCAD/Revit as your preference dictates and deliver professional, construction-ready drawings. I've reviewed your architectural files and am ready to begin immediately upon engagement. Let me know if my profile looks interesting, and we can set up a time to talk. Best regards, Elijah M
$700 AUD in 6 days
0.0
0.0

Hello, I reviewed your project requirements Commercial Gym Electrical Design - 13/09/2026 17:02 EDT and I am confident that I can deliver high-quality results that match your vision. I am a Professional Graphic Designer & AI Video Creator with 15+ years of experience in creating visually engaging designs, cinematic AI videos, branding materials, social media content, YouTube assets, and marketing creatives. ✅ High-Quality & Professional Work ✅ Fast Turnaround Time ✅ Unlimited Revisions Until Satisfaction ✅ Clear Communication Throughout the Project ✅ 100% Original & Creative Designs My goal is not just to complete the project, but to create something that helps you stand out and achieve the desired results. You can view my portfolio here: https://www.freelancer.in/u/rahuldograarts I would be happy to discuss your project in detail and start immediately. Looking forward to working with you. Best Regards, Rahul D. Graphic Designer | AI Video Creator
$250 AUD in 1 day
0.0
0.0

Hi, I can develop the complete electrical design package for your 600 m² commercial gym, including lighting, emergency lighting, power distribution, load calculations, SLDs, panel schedules, cable sizing, breaker selection, and containment routing. I can work with AutoCAD/Revit and Dialux/Relux and prepare clear, code-compliant drawings and a concise design report. Question: Which country or local electrical code should the design follow? Best regards, Mohamed Amine.
$500 AUD in 7 days
0.0
0.0

Gold Coast, Australia
Payment method verified
Member since Sep 10, 2026
$250-750 AUD
₹1500-12500 INR
$30-250 USD
₹1500-12500 INR
$250-750 AUD
₹600-1500 INR
$30-250 CAD
$250-750 USD
$15-25 USD / hour
$10-30 USD
₹1500-12500 INR
$15-25 USD / hour
$10000-20000 CAD
$250-750 AUD
₹600-1500 INR
$250-750 USD
£250-750 GBP
₹7500-8500 INR
$250-750 USD
$14 AUD
$250-750 USD