Käynnissä
Julkaistu
Maksettu toimituksen yhteydessä
I have a single-storey residential extension ready for Building Control sign-off and my insurer’s warranty. The roof layout has already been designed by the posi-joist supplier, so what remains is a full structural check and the accompanying calcs package covering three key elements: • Strip foundations bearing on clay soil • A 4 m wide opening that will be spanned by a new lintel (door set) • Interaction with the posi-joist roof to confirm overall stability and load paths The extension carries only light residential loads, but I still need stamped calculations, concise sketches or mark-ups, and any connection details necessary to keep the inspector happy. Please reference current UK codes (Eurocode or BS as appropriate), verify bearing pressures for the clay sub-grade, size the steel or engineered timber lintel, and confirm lateral restraint for the joisted roof. A brief summary note outlining your assumptions and safety factors will round off the submission. PDF output is fine, but an editable copy in either Tekla Tedds, Robot, Revit, or a clean spreadsheet would be a bonus for my records.
Projektin tunnus (ID): 40395461
11 ehdotukset
Etäprojekti
Aktiivinen 22 päivää sitten
Aseta budjettisi ja aikataulu
Saa maksu työstäsi
Kuvaile ehdotustasi
Rekisteröinti ja töihin tarjoaminen on ilmaista

Dear Client, We can complete a thorough structural check and deliver a clear calculation package for your residential extension ready for review. Our team has strong experience in foundation design lintel sizing and timber roof coordination using Eurocode and UK standards. We will verify strip foundations on clay soil assess bearing capacity and settlement and design the 4 m opening with an efficient lintel solution. We will also review the interaction with the posi joist roof to confirm stability load paths and lateral restraint. You will receive well structured calculations concise sketches and clear notes outlining assumptions and safety factors along with editable files for your records. Our approach ensures accuracy clarity and smooth coordination for approval. THE CALIFORNIA STUDIO
£250 GBP 2 päivässä
4,5
4,5
11 freelancerit tarjoavat keskimäärin £379 GBP tätä projektia

As an experienced Freelancer in the field of civil engineering and architectural design, I believe I am well-equipped to handle your project. My breadth of knowledge extends to building regulations, which aligns perfectly with your need for precise adherence to UK codes (Eurocode or BS). My expertise in structural design has allowed me to work effectively on a variety of residential projects, giving me the necessary perspective to handle this single-story extension with ease. Having worked extensively with various software including Tekla, Rhino, AutoCAD, and more, I can provide deliverables that suit your preference. My familiarity with Tekla Tedds, Robot, Revit, or clean spreadsheet usage may give your project that extra value you're looking for. Beyond just providing calculations and building designs within UK regulations, my end-to-end approach ensures a thorough delivery; which means detailed stamped calculations, sketches or mark-ups for easy comprehension and safety factor summary note.
£250 GBP 2 päivässä
7,3
7,3

As a seasoned civil engineer with a wealth of experience in structural design, I am confident that I can provide the comprehensive structural calculations and review that your residential extension requires. Throughout my career, I have developed an excellent understanding of both UK codes, including Eurocode and BS, and structural principles that encompass soil mechanics as well as steel and engineered timber design. This places me in a prime position to assess the bearing pressures for your clay sub-grade foundation and size the lintel needed for your 4m wide opening. In addition to my proficiency in AutoCAD, my expertise includes Tekla Tedds, Robot, and Revit -- all powerful tools that can not only provide accurate calculations but also deliver the clean spreadsheets or editable copies you desire for your records. My commitment to detail goes beyond calculations as I can also provide concise sketches or mark-ups alongside any connection details required by the inspector. Overall, my aptitude in 2D/3D modelling paired with my architecture background have fined tuned my eye for detail and problem-solving skills making me well-suited to ensure overall stability and load paths are assessed effectively without compromising on quality. I am excited to leverage these skills to complete your project satisfactorily, ensuring your Building Control sign-off and insurer's warranty are obtained seamlessly. Let's connect soon!
£266 GBP 1 päivässä
6,7
6,7

As a Civil Engineer with a wide range of skills, I am confident that I can expertly handle the structural calculations and review needed for your residential extension project. Your requirements align extremely well with my expertise in AutoCAD, Building Architecture, Building Regulations, and Civil Engineering, making me well-placed to deliver the precise stamped calculations, clear sketches, and satisfactory connection details that you need. I am eager to lend my skills and knowledge to bring this project to a successful completion within agreed timelines while ensuring Building Control sign-off and insurer's warranty requirements are met. Don't hesitate to reach out; let’s discuss in more detail how we can create satisfactory results together!
£251 GBP 1 päivässä
5,9
5,9

Hi, Could you confirm the exact location in the UK for precise local Building Control requirements and soil test data for the clay sub-grade? Also, do you have the posi-joist roof drawings and any existing foundation details or load assumptions available? I'm Mohand, a talented Structural Engineer and expert in Tekla Structures and SAP2000 with extensive experience in UK residential extensions requiring Building Control approval. I've delivered 50+ full structural calculation packages for single-storey extensions, including strip foundations on clay, lintel sizing for wide openings, and posi-joist roof stability verification per Eurocode 7 (geotechnical) and BS EN 1992/1993 standards. My work routinely verifies bearing pressures (typically 75-150 kPa safe capacity for firm clay), sizes steel/engineered timber lintels with 150mm bearings for 4m spans, and confirms load paths with lateral restraint details to satisfy inspectors. Using Tekla Tedds for editable outputs alongside stamped PDF calcs with sketches, mark-ups, connection details, and summary notes on assumptions/safety factors, I've achieved first-time sign-offs for insurers like LABC and NHBC.
£500 GBP 5 päivässä
5,2
5,2

As an interior designer who is not only passionate about transforming spaces but also dedicated to practicality and functionality, I believe I am an ideal candidate for this project. My extensive experience in building and architectural design, including the usage of AutoCAD and SketchUp, allows me to approach your needs from a unique perspective. I fully understand the importance of satisfactory Building Control sign-off and your insurer's warranty for your single-storey residential extension. In relation to your specific requests, I am well-versed in the use of Tekla Tedds, Robot, Revit-so providing you an editable copy of the calculations would be no challenges at all. My proficiency in this range of software also makes it easier for me to reference current UK codes, verify bearing pressures of clay sub-grade and ensure lateral restraint for the joisted roof. Lastly, my strong project management and communication skills give you the confidence that not only will all technical requirements be met with precision, but that you will also receive thorough documentation with supported mark-ups and sketches to ensure inspector satisfaction. My goal is to not just meet expectations but exceed them by delivering impeccable quality work within your budget. Please get in touch so we can discuss your project further!
£300 GBP 7 päivässä
3,2
3,2

As an experienced engineer in the field, I possess the essential skills you require for this project. Although my previous freelance work has primarily been centered around 3D designing and animation, my knowledge of AutoCAD and Building Architecture will combine synergistically to ensure exhaustive structural calculations and review for your residential extension. Completing it all, a distinguishing summary report outlining every assumption and safety factor utilized throughout the process will be provided. Choosing me will not only assure a meticulous job but also embrace potential bonus points like clean spreadsheets which may further facilitate your specific needs. Thank you!
£299 GBP 1 päivässä
4,4
4,4

Having navigated structural designs for numerous residential extensions, I understand the critical importance of achieving both Building Control compliance and insurer-grade documentation. I recently completed a similar masonry extension where my calculations were approved on the first submission, ensuring the homeowner met their strict insurance deadlines. My background allows me to identify structural efficiencies while ensuring total safety, regulatory adherence, and the specific technical peace of mind your insurer requires for the warranty. My approach begins with a review of your architectural plans to verify load paths and specify structural members, whether utilizing timber rafters or steel RSJs. I will perform rigorous calculations for dead, live, and wind loads in accordance with the latest Building Regulations using software like Tekla or SkyCiv. This includes detailed beam sizing, padstone specifications, and foundation assessments to ensure the new structure integrates with the existing dwelling. Every calculation is presented in a clear report designed for immediate approval by Building Control and insurance underwriters, minimizing the risk of iterative queries. To ensure the fastest sign-off, could you clarify if the extension involves any internal wall removals or if you have specific soil condition reports for foundation depths? Additionally, are there any unique roof loadings, such as heavy tiling or solar panels, that need to be factored into the final model? I am available to review your drawings via chat today to ensure we align with your timeline; feel free to reach out if you would like to schedule a brief call to finalize the scope and start the review immediately.
£508 GBP 21 päivässä
0,0
0,0

As an experienced Architect, Civil, and Structural Engineer, I am well-equipped to handle the detailed nature of your project. My deep understanding of residential design and construction allows me to evaluate structural components with precision while considering functional and aesthetic aspects. I have a proven track record of integrating engineering principles with architectural practice - a critical skill for this assignment's need for a full structural check and the accompanying calculations package. I understand the importance of adherence to Building Control regulations, safety factors, and UK codes - all elements that will be comprehensive in my work. My solid Grip on AutoCAD and familiarity with Tekla Tedds, Robot, Revit gives flexibility in output formats while ensuring the highest level of accuracy. Perhaps most importantly, I offer a holistic approach to projects - bridging the gap between structural stability and overall design cohesion. This perfectly aligns with your need for confirmation of overall stability and load paths between foundations, lintel span, and joisted roof. Choosing me for your project guarantees not just stamped calculations and concise sketches but a comprehensive solution that maximizes efficiency and complies perfectly with relevant building regulations. I eagerly await the opportunity to excecute this task effectively for you.
£500 GBP 7 päivässä
0,0
0,0

Hello, I understand that the primary technical challenge in your project involves confirming the structural integrity of your residential extension, particularly focusing on the strip foundations, the lintel spanning, and the interaction with the posi-joist roof. This is critical as inaccurate calculations could lead to compliance issues with Building Control and potential safety risks. Ensuring these elements are properly assessed against current UK codes, such as Eurocode or BS, is essential to meet your insurer's warranty requirements. With my background in structural calculations and familiarity with UK building codes, I can provide the stamped calculations and detailed sketches you need. My experience includes assessing foundation bearing pressures and sizing structural elements like steel and timber lintels, ensuring compliance and safety. I have worked on similar projects where I delivered concise documentation alongside calculations, which facilitated smooth inspections and approvals. For this project, I propose a methodical approach that includes: - Reviewing the existing designs and requirements. - Performing the necessary calculations and checks. - Creating detailed sketches and connection details. - Compiling a summary note that outlines assumptions and safety factors. What are your specific timelines for this submission? Do you have any preferred formats for the final deliverables beyond those mentioned in your request? Best, Shaun
£410 GBP 7 päivässä
0,0
0,0

Basingstoke, United Kingdom
Maksutapa vahvistettu
Liittynyt huhtik. 24, 2026
$250-750 USD
₹400-750 INR/ tunnissa
$10-30 USD
$1500-3000 USD
₹12500-37500 INR
$10000-20000 AUD
€8-30 EUR
$250-750 USD
₹12500-37500 INR
₹600-4000 INR
₹1500-12500 INR
$3000-5000 USD
$25-50 AUD/ tunnissa
£10-15 GBP/ tunnissa
$250-750 AUD
₹12500-37500 INR
₹700-900 INR
₹600-1500 INR
₹1500-12500 INR
$20-150 NZD