
Closed
Posted
Paid on delivery
I need a complete, code-compliant fire-sprinkler layout for a commercial building that is dedicated to retail stores. The scope covers every sales floor, back-of-house corridor and stockroom so shoppers, staff and inventory are fully protected. Please base the design on current NFPA standards and any local amendments. I will supply floor plans in DWG and PDF the moment we start; you return a coordinated sprinkler drawing (AutoCAD or Revit is fine), hydraulic calculations, a pipe and head schedule, and a concise material take-off ready for the estimator. All mains, branch lines, hangers and valves must be shown clearly, with zones and hazard classifications called out so the authority having jurisdiction can review without delay. I’ll review for clear coverage, correct density, balanced flow, and clean layer management. Once those items check out, the project is complete and you can invoice right away.
Project ID: 40644601
41 proposals
Remote project
Active 5 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
41 freelancers are bidding on average $399 USD for this job

With a career dedicated to transforming architectural concepts into tangible designs since 2012, I am Syed Furqan, your top-rated expert in fire fighting drawings and CAD conversions. You need an efficient, code-compliant fire sprinkler layout that guarantees the safety of all occupants and minimizes any delays with the jurisdiction. Well versed in the NFPA standards, I will provide you with well-coordinated sprinkler drawings (AutoCAD or Revit), hydraulic calculations, a precise pipe and head schedule, and a comprehensive material take-off ready for estimation. Our engagement not only ends once the project is complete but rather marks the beginning of a long-lasting relationship. My skill-set also extends to 2D floor plans that are key for Real Estate marketing, such as yours. By incorporating my expertise on lease, proposed, existing & permit drawings, you can rest assured of clear cut precise coverage, correct density, balanced flow and clean layer management. Additionally proficient in MEP drawing,I bring about a cross-discipline understanding that ensures the final product not only meets your requirements but also integrates perfectly with other building systems. Don't hesitate any further; hire me now and let's transform your project vision into reality while maintaining top-notch safety standards
$250 USD in 2 days
8.0
8.0

As a Structural Engineer, Architect and BIM Specialist with years of experience in the field, I am confident that I am more than equipped to handle your commercial retail sprinkler design project. My adept skills in AutoCAD and Building Architecture will ensure I deliver a fire-sprinkler layout that is completely code-compliant and in line with NFPA standards. Drawing on my expertise, your floor plans will be transformed into a coordinated sprinkler layout, accompanied by hydraulic calculations, a pipe and head schedule as well as a precise material take-off – all ready for your estimator to work with straightaway. What sets me apart from other candidates is my deep understanding of the importance of clear coverage, correct density, balanced flow and clean layer management when it comes to fire safety. This knowledge combined with my rigorous attention to detail means that every aspect of your project will be thoroughly reviewed and optimized to meet the highest standards. The successful completion of your project is not only about receiving accurate drawings but encompassed by the timely approval from the authority having jurisdiction. With me on board, you can count on having precisely that. Every element needed for review will be included in the deliverables - clear indications of zones and hazard classifications will help hasten the review process so we can move forward without delay.
$250 USD in 1 day
6.5
6.5

Hello there, This is Sajjad Khan. I am an Architect with more than 6 years of experience in my field in Design and Visualization, MEP, Structural etc. I am experienced in Revit, Rhino, Twinmotion, 3ds Max, AutoCAD, SketchUp, Lumion, D5 Render and Blender as well. I have recent experience in similar projects also. It’s an interesting project and I am really excited to start working on it. Please Get in Touch with me for further discussion on the project.. Thanks Sajjad Khan
$250 USD in 7 days
6.3
6.3

Hi, I can help with the **Commercial Retail Sprinkler Design** and prepare a clear, professional layout focused on proper sprinkler coverage, practical installation, and accurate documentation. Before starting, I’d like to review the **retail floor plan, ceiling/layout details, building information, required design standard/code, and expected deliverables** so I can understand the project properly and provide exactly what you need. I can also coordinate the sprinkler layout with the architectural/MEP plan and make sure the final drawings are clean, accurate, and ready for your intended use. **Could you share the floor plans and any existing sprinkler/MEP drawings or project specifications?** Once I review them, I can confirm the approach, deliverables, and timeline. Best regards, Kirandeep K.
$251 USD in 2 days
5.6
5.6

How are you? Your project matches well with my skills. Please check my profile. https://www.freelancer.com/u/lamvanduong I'll provide all drawing sets and wonderful result such as PDF, DWG(2D drawings), rendering images and BIM(3D model). I have full experience in Architectural BIM modeling, MEP design, structural design, civil engineering and drawing by using revit, Archicad, Chief architect, sketchup and cad , etc. I'll use your country building code to permit. Let's discuss more about project and start together. Best regards
$250 USD in 2 days
5.6
5.6

With my robust background in Architecture and Civil Engineering, I believe I'm perfect for your Commercial Retail Sprinkler Design project. Throughout my career, I've developed a strong command of AutoCAD, which will allow me to deliver the coordinated sprinkler drawing you're seeking with precision. In addition, I've also honed my abilities in providing comprehensive material take-offs that can be readily utilized by estimators - a skill that will prove invaluable for your project. Being meticulous is a virtue of mine as well; whether it's scrutinizing for clear coverage, correct density, balanced flow, or clean layer management, no detail will escape my attention. When I submit the final design to you, you can rest assured that it has undergone thorough review and checks. Building on all these strengths, I am confident I am the right freelancer to tackle this project for you.
$500 USD in 7 days
5.7
5.7

Hi there, I understand you need a complete commercial fire-sprinkler design for a retail building, including sales areas, corridors, and stockrooms. I can develop the coordinated sprinkler layout in AutoCAD/Revit with clearly shown mains, branch lines, sprinkler heads, valves, zones, hazard classifications, and clean layer organization. A quick question: which city/state is the project located in, and will you provide the building floor plans along with the available water-supply information/test data? These are important for determining the applicable NFPA requirements and hydraulic calculations. I’d be glad to review the drawings and develop the sprinkler documentation for AHJ review. Best regards, Qayyom
$250 USD in 2 days
5.5
5.5

Hello, I can deliver a complete commercial fire-sprinkler design package for your retail building, coordinated directly with the supplied DWG/PDF architectural plans and prepared for AHJ review. My scope includes: • Complete sprinkler layout for sales areas, corridors, stockrooms and back-of-house spaces • Sprinkler head locations, pipe routing, mains and branch lines • Hazard classifications and design zones • Valves, hangers and required system components • Pipe sizing and hydraulic calculations • Sprinkler/head and pipe schedules • Concise material take-off for estimating • Clear AutoCAD/Revit drawings with organized layers • Print-ready PDF submission set I will design around the applicable NFPA standards and local amendments, confirming the governing edition with the project jurisdiction/AHJ. Coverage, spacing, density, pressure, flow and hydraulic balance will be checked before final delivery. I understand that retail stockrooms can have different storage hazards than sales areas, so I will review the actual occupancy and storage conditions rather than applying one classification across the entire building. I will coordinate the sprinkler system with the architectural layout and flag conflicts or missing information before finalizing instead of making unsupported assumptions. Please provide the architectural DWG/PDF plans.
$275 USD in 4 days
5.5
5.5

Hello, I have experience preparing commercial fire-sprinkler layouts for retail buildings, including sales floors, stockrooms, corridors, hazard classifications, head spacing, pipe routing, and hydraulic calculation coordination. I am interested in this project because the system needs to be clear, code-compliant, and organized well enough for AHJ review and estimator pricing. I will review your DWG/PDF floor plans, occupancy areas, ceiling conditions, water supply data, and local requirements, then prepare a coordinated AutoCAD or Revit sprinkler plan based on NFPA standards. I will show mains, branch lines, heads, valves, hangers, zones, schedules, hydraulic calculations, and a concise material take-off. If sealed fire-protection drawings are required, I do not personally hold that licensure, but I can coordinate stamped results through an actively licensed fire protection engineer. Thanks for reading my proposal. Edwin
$500 USD in 7 days
5.3
5.3

I’d be glad to handle your commercial retail fire-sprinkler design project with accuracy and attention to code compliance. I can develop a complete coordinated sprinkler layout based on the latest applicable NFPA standards and local requirements. My scope will include sprinkler head layout, mains and branch lines, valves, hangers, zoning, hazard classifications, and clear AutoCAD/Revit layer management. I will also prepare hydraulic calculations, pipe and sprinkler head schedules, and a concise material take-off suitable for estimating and AHJ review. Once you provide the DWG/PDF floor plans, I’ll coordinate the design carefully to ensure proper coverage, density, balanced flow, and practical routing. Give me one opportunity to handle your project. I assure you of dedicated, accurate, and professional work with timely delivery. I look forward to working with you.
$266 USD in 5 days
3.5
3.5

With over a decade of experience in transforming commercial spaces into functional and beautiful areas, I am confident in my ability to provide you with the precise sprinkler layout you need for your retail building. My expertise in using AutoCAD and building architecture ensures I will be able to not only produce a design based on NFPA standards but also incorporate any local amendments that may be relevant to your project. I understand the significance of keeping shoppers, staff, and inventory safe in a retail environment. Thus, my keen focus on detail, balanced flow, and clean layer management ensures proper coverage and correct density for efficient fire protection. Additionally, I guarantee timely completion of all phases of the project, from preparing coordinated sprinkler drawings in AutoCAD or Revit to providing thorough hydraulic calculations, pipe, head schedule and comprehensive material take-off ready for your estimator. I am also skilled at clearly depicting mains, branch lines, hangers, valves with attention given to zones and hazard classification such that it facilitates review by the authority having jurisdiction without delay. Let's work together to make this project a success.
$250 USD in 5 days
3.7
3.7

Hello Skilled fire sprinkler designer with over 10 years of experience in designing fire protection and fire alarm system for commercial and residential buildings. Extensive knowledge with Los Angeles City and Local Codes. Proficient in AutoCAD and hydraulic calculation software for designing and modeling fire protection systems. Proficient in Foam and Water Mist system designing Proficient in FM200, Co2, Novec & Kitchen hood Fire suppression system designing. In-depth knowledge of NFPA standards and local building codes for fire safety compliance (NFPA13, 13D,13R and NFPA 14,20,72).
$250 USD in 3 days
3.6
3.6

I am pleased to submit my proposal for your Commercial Retail Sprinkler Design project. I can assist with developing accurate and practical fire sprinkler system designs for retail spaces, considering the building layout, occupancy classification, ceiling conditions, storage areas, and applicable fire protection requirements. My focus is on producing clear, coordinated, and installation-ready design documentation. I can prepare sprinkler layouts, hydraulic calculations, riser and piping details, equipment specifications, and related design drawings while coordinating with architectural, structural, electrical, and MEP requirements. I will carefully review the project information and ensure the design is efficient, properly documented, and suitable for permitting and installation in accordance with the applicable codes and standards. I understand the importance of accuracy, safety, and timely delivery in commercial fire protection projects. I am committed to providing professional-quality work, responding promptly to revisions, and maintaining clear communication throughout the project. I would welcome the opportunity to contribute my sprinkler design expertise and deliver a reliable solution tailored to your retail project requirements.
$250 USD in 7 days
2.9
2.9

Hello! I understand you need a complete commercial retail fire-sprinkler design package coordinated from DWG/PDF architectural plans, including sprinkler layouts, hazard classifications, hydraulic calculations, schedules, and an estimator-ready material take-off. I have experience developing NFPA-based fire protection layouts with coordinated mains, branch lines, heads, valves, hangers, zones, and hydraulic calculations, with careful attention to coverage and water-demand requirements. I’ll review the architectural plans and occupancy/storage conditions, establish the applicable hazard classifications and design criteria, develop the sprinkler and piping layout, perform hydraulic calculations, coordinate the system with the building, and issue organized AutoCAD/Revit drawings and schedules. NFPA 13 requires the design approach and water demand to be determined based on the applicable occupancy/hazard and hydraulic calculation method, so the final design will be based on the actual retail and stockroom conditions rather than assumptions.
$250 USD in 7 days
2.8
2.8

Hello, You need a complete commercial fire sprinkler design package covering sales floors, corridors, stockrooms, hydraulic calculations, schedules, and material take-off, coordinated for AHJ review. I can prepare the sprinkler layout with clearly identified zones, hazard classifications, mains, branch lines, heads, valves, and hanger locations, together with the hydraulic calculation package, pipe/head schedule, and estimator-ready material take off. The design would be coordinated against the applicable NFPA 13 edition and local amendments; NFPA 13 covers sprinkler location, piping, valves, hanging/support, design approaches, and plans/calculations. Also a quick question, which city/state and AHJ is the commercial building located under, and what NFPA 13 edition has been adopted there?
$250 USD in 1 day
3.0
3.0

Hello, I am a licensed Professional Engineer with 15+ years of experience in commercial fire protection and sprinkler system design. I understand that you need a complete code-compliant sprinkler design for a retail building covering sales areas, corridors, stockrooms, and back-of-house spaces, with clear hazard classifications, zoning, pipe sizing, and coordinated system layout. I can prepare the sprinkler plans in AutoCAD or Revit, including mains, branch lines, valves, hangers, head locations, hydraulic calculations, pipe/head schedules, and a concise material take-off for estimating. The design will follow applicable NFPA standards, including NFPA 13 where applicable, along with local fire department and AHJ amendments. I am interested in this project. Looking forward to working with you. Warm regards
$500 USD in 7 days
2.4
2.4

Hello! I will design a coordinated retail fire-sprinkler system covering sales floors, corridors and stockrooms, with hazard classifications, spacing, density, zoning and hydraulic demand established under current NFPA 13 and local AHJ amendments. I will draft mains, branches, heads, valves and hangers in AutoCAD, complete hydraulic calculations, and deliver review-ready drawings, pipe/head schedules and a concise material take-off with clean layers. Portfolio: https://www.freelancer.com/u/olenav24 Best regards, Olena
$500 USD in 7 days
2.0
2.0

Hi there ? I have extensive experience using Revit, Chief architect, Autocad and archicad for architectural and MEP modeling, including creating detailed BIM models, floor plans, and construction documentation. I can ensure your project is accurately modeled with full parametric functionality for easy updates. I can start with an initial model draft for your review. Looking forward to collaborating! Best regards
$250 USD in 3 days
2.0
2.0

With my advanced skills in REVIT, AUTOCAD, BIM, and SketchUp, I've honed my ability to create intricate, detailed, and practical designs while working under different project demands. My training in BIM ensures that all your architectural, structural and MEP requirements are not only met but also harmoniously coordinated, minimizing costly construction errors. In the case of sprinkler design specifically, I'm well-versed in rendering the services you need: from 3D modeling using Revit based on your supplied DWG and PDF floor plans to creating a hydraulic calculation for balanced flow and a pipe/head schedule. My understanding of codes such as NFPA in addition to local amendments guarantees that your project complies with regional regulations and authorities will review it promptly. Moreover, as an intuitive thinker with excellent problem-solving instincts and a responsible approach to precision, designing a retail space that not only meets code requirements but also supports effective stockroom management, staff workflow optimization and customer safety will come naturally to me. I look forward to combining your project vision with my skills to provide you with a top-tier fire-sprinkler layout that doesn't just tick all boxes but enhances the productivity of your commercial space while ensuring maximum protection.
$500 USD in 1 day
0.6
0.6

I understand you require a comprehensive, code-compliant fire sprinkler design for a retail commercial building, similar to projects where I've delivered integrated AutoCAD layouts with precise hydraulic calculations and material take-offs. My focus is on ensuring complete protection for sales floors, back-of-house areas, and stockrooms, adhering strictly to NFPA standards and local amendments. My approach involves importing your DWG/PDF floor plans into Revit, where I will perform a detailed 3D model of the sprinkler system. This includes precise placement of sprinkler heads, accurate routing of mains and branch lines, and specification of appropriate hangers, all while cross-referencing NFPA 13 requirements for coverage and spacing. Hydraulic calculations will be performed using industry-standard software, generating a detailed report. The final deliverables will include a coordinated sprinkler drawing, hydraulic report, pipe and head schedule, and a concise material take-off. To ensure the design perfectly aligns with your project's specific needs, could you clarify if there are any particular occupancy hazard classifications for the retail spaces that differ from standard retail? Additionally, are there any specific aesthetic considerations for visible sprinkler heads in sales areas? I'm available to discuss these details further and answer any immediate questions you may have.
$600 USD in 21 days
4.7
4.7

Valencia, United States
Member since Aug 13, 2026
$250-750 USD
$30-250 USD
$250-750 USD
€30-250 EUR
$10-30 USD
£250-750 GBP
$10-30 USD
€8-30 EUR
₹600-1500 INR
min $50 AUD / hour
€30-250 EUR
$250-750 SGD
$250-750 USD
$250-750 USD
$250-750 USD
₹12500-37500 INR
$30-250 USD
£18-36 GBP / hour
₹750-1250 INR / hour
₹37500-75000 INR