
Suljettu
Julkaistu
Maksettu toimituksen yhteydessä
I have an existing Siemens S7 program that currently drives the machinery on a manufacturing production line, and I need the exact same functionality reproduced in RSLogix 5000 for an Allen-Bradley platform. The original code handles all real-time control for motors (G120), valves, position valves/solenoid. You will receive: • The complete Step 7 project archive, I/O tag list I/O list for RSlogix controller including the model numbers of the I/O What I expect back: • An RSLogix 5000 (Studio 5000) project file that mirrors the existing sequences, timers, and alarms. • A brief cross-reference document mapping every original S7 tag, DB, and FC to its new controller-scoped or program-scoped tags. • Confirmation the code compiles without errors on a ControlLogix target and that all routine names, comments, and rung descriptions are preserved or improved for clarity. • Port siemens profisafe to allen bradley safety equivalent for ESTOP of drives. (guard logic) • Convert function blocks (SCL and LAD) to communicate with G120 VFDs via profinet to Allen Bradley equivalent (ethernet).
Projektin tunnus (ID): 40264550
33 ehdotukset
Etäprojekti
Aktiivinen 8 päivää sitten
Aseta budjettisi ja aikataulu
Saa maksu työstäsi
Kuvaile ehdotustasi
Rekisteröinti ja töihin tarjoaminen on ilmaista
33 freelancerit tarjoavat keskimäärin $2 118 USD tätä projektia

Hello, With an in-depth knowledge of Electrical Engineering, Electronics and Microcontrollers, I am confident that I can offer you an unrivaled service. I have notable experience in PLC programming across multiple platforms including Siemens S7 and Allen-Bradley's RSLogix 5000 - a perfect match for your project demands. Over the years, I have replicated code on various systems, dealt with real-time control operations similar to your manufacturing production lines and successfully converted function blocks from one platform to another. The Live Experts team, I lead, understands the significance of delivering precise work and we are dedicated to achieving just that in your project. We will carefully convert every original S7 tag, DB, FC into their appropriate counterparts ensuring full mirror functionality in the new RSLogix system. Alongside this, I will provide a comprehensive cross-reference document outlining each transformation for easy comprehension. Notably, my team and I are well-versed in porting Siemens Profisafe to Allen-Bradley safety equivalent - a crucial requirement mentioned in your project description. Rest assured that we will not only get the job done as expected but also ensure that all routine names, comments, rung descriptions are preserved or even improved for clarity. Ultimately, by choosing us you can be confident of a seamless conversion process executed by seasoned professionals with proven results. Thanks!
$3 000 USD 5 päivässä
8,3
8,3

As an Electrical Engineer with extensive experience in the embedded systems field, I believe I am perfectly positioned to seamlessly convert your Siemens S7 program to the RSLogix 5000 platform. My proficiency in working with a wide range of microcontrollers, including STM32, Texas Instruments C2000, and Microchip PIC32, has provided me with an in-depth understanding of different programming languages, including LAD and SCL. This knowledge will prove invaluable in transferring your existing sequences, timers, and alarms precisely. In addition to masterful software skills, I have a significant edge in hardware proficiency. A robust mastery of board-level designs using Altium Designer enables me to thoroughly understand the circuitry behind your industrial setup. This knowledge extends to Ethernet connectivity and safety requirements such as the profinet to Allen Bradley equivalent for G120 VFDs and port Siemens profisafe to Allen Bradley safety equivalent for ESTOP. Finally, I want to assure you that my dedication does not wane at completion; instead, it amplifies.
$3 000 USD 45 päivässä
8,2
8,2

Hi, KINDLY READ THROUGH MY PROPOSAL THIS IS WHAT I WILL DO - Fully convert your Siemens S7 program (LAD + SCL) to Studio 5000 / ControlLogix, preserving all sequences, timers, alarms, interlocks and machine logic. - Port PROFIsafe safety functions to GuardLogix safety (ESTOP, drive guard logic, safety I/O mapping). - Replace PROFINET G120 communication with EtherNet/IP (using AOI for G120 or migrate to PowerFlex 525/755 if preferred). - Deliver a clean, compiled RSLogix 5000 project with improved rung comments and descriptions. - Provide a detailed cross-reference document (Excel) mapping every S7 tag/DB/FC/OB to the new AB tags. - Include commissioning guide for download and first-run validation. RELEVANT PROJECTS - 2025: Full S7-1500 → ControlLogix migration for packaging line (G120 drives + PROFIsafe) – 100% functionality match, live since March. - 2024: S7-1200 to GuardLogix retrofit for automotive assembly (safety + VFD comms) – completed in 18 days. QUESTIONS - Exact ControlLogix CPU model and firmware revision? - Do you want to keep the existing G120 drives or migrate to PowerFlex? - Safety PLC type (GuardLogix 5570/5580 or 5380)? - Any specific AOI preference for G120? S7-to-Logix migration specialist. Can deliver first working version in 5days after receiving the Step 7 archive. I am Ready to start immediately — send the project and let’s get your line running on AB!
$1 500 USD 4 päivässä
6,3
6,3

Hello, I understand you need a full port of your Siemens S7 control logic to RSLogix 5000 (Studio 5000) on a ControlLogix platform, preserving real-time motor control (G120), valves, position valves/solenoids, timers, alarms, and safety logic. I will deliver a mirrored, well-documented RSLogix 5000 project that reproduces the sequences, timing, and alarm behavior, with a cross-reference mapping for every original S7 tag, DB, and FC to the new tags (either controller-scoped or program-scoped). I’ll ensure the code compiles cleanly on the ControlLogix target, with preserved or improved rung descriptions and comments for clarity. I will port Siemens PROFIsafe ESTOP logic to Allen-Bradley safety equivalence, and translate function blocks (SCL and LAD) to communicate with G120 VFDs over Profinet/Ethernet using the AB platform. The project will include the complete RSLogix 5000 file set and a validation plan showing compilation results and safety mappings. What is the preferred version of Studio 5000 and exact ControlLogix model for the target system? Are there any specific G120 drive models or I/O modules that have non-standard mappings to account for during porting? Best regards,
$3 000 USD 28 päivässä
6,0
6,0

Hi, how are you doing? I went through your project description and I can help you in your project. your project requirements perfectly match my expertise. We are a team of Electrical and Electronics engineers, we have successfully completed 1000+ Projects for multiple regular clients from OMAN, UK, USA, Australia, Canada, France, Germany, Lebanon and many other countries. We are providing our services in following areas: Embedded C Programming. VHDL/Verilog, Quartus/Vivado, LabVIEW/ Multisim/PSPICE/VLSI MATLAB/SIMULINK Network Simulator NS2/NS3 Microcontroller like Arduino, Raspberry Pi, FPGA, AVR, PIC, STM32 and ESP32. IDEs like Keil MDK V5, ATmel studio and MPLab XC8. PLCs / SCADA PCB Designing Proteus, Eagle, KiCAD and Altium IOT Technologies like Ethernet, GSM GPRS. HTTP Restful APIs connection for IOT Communications. Also, we have good command over report writing, I can show you many samples of our previous reports. Kindly consider us for your project and text me so that we can further discuss specifically about your project's main goals and requirements.
$2 250 USD 7 päivässä
6,1
6,1

Hello, I understand you need a full conversion of your Siemens S7 program to RSLogix 5000 (Studio 5000) for Allen-Bradley, preserving all real-time control logic for motors (G120), valves, solenoids, timers, and alarms. I will recreate every sequence, function block (SCL and LAD), and communication interface with G120 VFDs over Profinet, translating to Allen-Bradley Ethernet protocols, and port the Siemens ProfiSafe logic to the AB safety equivalent for ESTOP and guard logic. Deliverables: fully compiled RSLogix 5000 project, cross-reference mapping all S7 tags, DBs, and FCs to the new program, and verification that routine names, comments, and rung descriptions are preserved or enhanced. The project ensures seamless functionality replication and safety compliance. Clarification Questions: Are there any custom S7 libraries or function blocks beyond standard Siemens FCs that need special attention? Should I simulate or test the converted logic on a virtual ControlLogix before deployment on the production PLC? Thanks, Asif
$3 000 USD 15 päivässä
5,2
5,2

Best Siemens Allen-Bradley ControlLogix Migration Expert ⭐⭐⭐⭐⭐ Hi, Thank you for posting your project, “Siemens S7 to RSLogix Conversion.” I’ve reviewed your requirements and can help you accurately migrate your existing production-line control logic from a Siemens S7 platform to Allen-Bradley ControlLogix Studio 5000, while preserving all machine behavior, safety functions, and real-time performance. I bring 11+ years of experience in motor drive control, safety systems, and cross-platform migrations. I’ve worked extensively with Step 7 / TIA Portal and RSLogix 5000 / Studio 5000, handling conversions involving motors, valves, solenoids, and VFD communication in live manufacturing environments. ✅ How I’ll Help You Succeed 1. Convert the full Siemens S7 program into a clean, fully functional Studio 5000 project with identical sequencing, timing, and alarm behavior. 2. Convert SCL and LAD function blocks to communicate with G120 VFDs, replacing PROFINET with the appropriate EtherNet/IP control model. 3. Deliver well-commented, compile-clean logic that is easy to maintain and verify on the target ControlLogix hardware. ✅ Before I start, one quick question: Which ControlLogix CPU and safety controller models are you targeting, and do you want the migration validated against real hardware or controller emulation first? If you share that, feel free to message me, and we can align quickly. Best regards, Prat PCB Must Innovations
$2 000 USD 12 päivässä
6,3
6,3

Hi, I am a senior controls engineer with 12+ years in Siemens S7 (Step 7) and Allen-Bradley ControlLogix platforms, having completed 25+ PLC migrations and 10 full production line retrofits with zero unplanned downtime during commissioning. I have converted complex S7 LAD/SCL projects with 1500+ I/O and PROFIsafe safety into Studio 5000 architectures, integrating 30+ VFDs per system while maintaining scan determinism and full alarm traceability. Approach: ✅ I will review the Step 7 archive, map all OB/FB/FC/DB structures, and define equivalent controller/program tags, UDTs, and AOIs in Studio 5000. ✅ I will translate SCL and LAD into optimized Logix routines, preserving sequences, timers, interlocks, and alarms with improved naming and rung comments. ✅ I will replace PROFINET G120 communication with Ethernet/IP drive control, mapping command/status words and diagnostics into reusable AOIs. ✅ I will convert PROFIsafe E-STOP logic into GuardLogix safety routines using CIP Safety and validate clean compilation on the target firmware. Questions: ✅ Is the target controller standard ControlLogix or GuardLogix, and which firmware revision must be matched? ✅ Which PowerFlex model will replace the G120 to define control/status structure and safety interface? ✅ Must the existing alarm philosophy remain identical, or can ALMD/ALMA instructions be implemented? Best, Yaroslav
$2 200 USD 7 päivässä
4,1
4,1

Hi, I hope you're you read this in good spirits! I'm a seasoned Controls Engineer, with special interest in Safety. My day-to-day job involves programming PLC mainly but not limited to Siemens. I believe I can deliver this to you in RSLogix 5000 despite not being my main choice for PLCs. I'm especially interested in your request for the E-stop and guarding safety migration, as a CMSE® I will make sure this function is translated without compromising the already archived safety performance levels as to EN13849-1 (PL) or the Safety Integrity Level (SIL) as per IEC 62062. If you're interested in working with me for the benefits I listed in the project milestons, let's have a chat. Best and most professional regards, Dhia Baali, MIET, CMSE®
$1 850 USD 21 päivässä
3,2
3,2

⭐⭐⭐⭐⭐ I can migrate your Step7 S7 program to a Studio 5000/ControlLogix project that mirrors the existing sequences, timers, alarms, and operator behavior—including a clean cross-reference (DB/FC/tag → Logix tag/routine/AOI) and a build that compiles error-free on the target. I’m comfortable translating mixed LAD/SCL into Logix Ladder + Structured Text, preserving rung comments and improving clarity where it helps maintenance. Milestones: Review Step7 archive + I/O lists + sequence map Build Logix tag model + routines (state logic, timers, alarms) Convert S7 FC/FB/DB structures into Logix programs/AOIs Drives + comms plan: G120 PROFINET → AB EtherNet/IP equivalent (gateway or redesign) Safety: PROFIsafe E-stop/guard → GuardLogix/CIP Safety equivalent + safety task structure Compile check + deliver project + full mapping document Key questions (to lock scope fast): • Are the Siemens G120 drives staying, or can they be replaced with AB drives? • What ControlLogix CPU + Safety CPU (GuardLogix) and safety I/O models are selected? • Do you need exact alarm text/HMI tags preserved too? If you want a true “same machine behavior” outcome, this is the right way to do it.
$2 250 USD 7 päivässä
3,0
3,0

Hello, I have executed multiple Siemens-to-Allen-Bradley migration projects involving full production line logic, safety systems, and drive communication layers. This is not a simple code translation — it requires architectural restructuring while preserving deterministic behavior. I will: • Reverse-engineer the Step 7 project (OB/FB/FC/DB, SCL & LAD) • Rebuild the logic in Studio 5000 with clean Controller/Program tag architecture • Maintain sequence timing, interlocks, and alarm behavior • Deliver a detailed cross-reference mapping document • Ensure clean compilation on a ControlLogix target • Convert PROFIsafe concepts into GuardLogix/CIP Safety equivalent • Implement EtherNet/IP drive communication for G120 with structured UDT/AOI design My approach focuses on deterministic scan behavior, maintainability, and commissioning readiness — not just syntax conversion. You will receive a well-structured, documented, production-ready ACD project. Let’s discuss the controller model and safety hardware to align architecture before starting. I am ready to begin immediately.
$1 700 USD 15 päivässä
2,8
2,8

Hi, As a Master’s graduate in Automatics and Systems, I specialize in cross-platform PLC migrations. I will convert your Siemens Step 7 project into a robust Studio 5000 architecture, ensuring that the timing, sequences, and safety protocols mirror your existing production line exactly. My Execution Plan: 1. Logic Conversion: I will manually port your SCL/LAD blocks into Studio 5000 (AOIs and Routines), ensuring that DBs and FCs are correctly mapped to Controller/Program-scoped tags. 2. VFD Integration: I will convert the G120 Profinet communication into the Allen-Bradley EtherNet/IP equivalent, utilizing Add-On Instructions (AOIs) for seamless drive control. 3. Safety Migration: I will port the Profisafe logic to GuardLogix safety routines, ensuring the E-Stop and drive safety functions meet the same SIL/PL standards. 4. Documentation: You will receive a detailed Cross-Reference Map and a fully commented project file that compiles error-free on your ControlLogix target. Technical Deliverables: 1. Complete .ACD project file (Studio 5000). 2. Tag & Logic Mapping Document (S7 to AB). 3. Optimized AOIs for G120 over EtherNet/IP. I understand the criticality of real-time control for valves and motors, and I am ready to start the conversion process as soon as I receive your archive. Best regards, Zakaria L
$1 500 USD 7 päivässä
2,5
2,5

Hello, I went through your project carefully, and the core challenge is clear: reproducing the exact functionality of your Siemens S7 program on RSLogix 5000 is a meticulous task requiring a deep understanding of both platforms. This isn't a surface-level task, it needs someone who comprehensively understands PLC programming and can execute without hand-holding. I've successfully managed similar conversions, ensuring precision and clean execution. My approach involves a thorough review of the provided Step 7 project archive and I/O lists, followed by crafting an RSLogix project that mirrors all sequences, timers, and alarms. I also guarantee a clear cross-reference document and error-free compilation on a ControlLogix target, enhancing clarity throughout. If this aligns, I can start immediately and deliver a fully functional project within 10 business days. One quick question before I proceed: what is the expected timeline for completion on your end? Best regards, Muskan
$1 500 USD 2 päivässä
2,0
2,0

With my comprehensive skill set in Electrical Engineering and Electronics, I am your ideal candidate for this Siemens S7 to RSLogix Conversion project. In addition to my proficiency in programming languages such as Python, C, and C++, I possess substantial experience in PLC programming—undoubtedly a great asset for this undertaking. On top of ensuring that your existing Siemens S7 program functionality is flawlessly replicated on an Allen-Bradley platform using RSLogix 5000, I will deliver a comprehensive cross-reference document mapping all S7 tags, DBs, and FCs to their corresponding Allen-Bradley tags. You can rest assure the code will be error-free on a ControlLogix target with routine names, comments, and rung descriptions properly preserved or improved for enhanced clarity. Furthermore, my understanding of Siemens Profisafe and Allen-Bradley ESTOP systems will facilitate an efficient porting of the former to the latter ensuring safety breaches are handled effectively. Finally, I have experience converting function blocks (SCL and LAD) to communicate with G120 VFDs via Profinet; this means that I can deliver on the task of integrating your G120 VFDs with allen bradley Ethernet efficiently.
$1 500 USD 7 päivässä
2,3
2,3

Hey , I just finished reading the job description and I see you are looking for someone experienced in Electrical Engineering, Microcontroller, Alarm Management and Electronics. This is something I can do. Please review my profile to confirm that I have great experience working with these tech stacks. While I have few questions: 1. These are all the requirements? If not, Please share more detailed requirements. 2. Do you currently have anything done for the job or it has to be done from scratch? 3. What is the timeline to get this done? Why Choose Me? 1. I have done more than 250 major projects. 2. I have not received a single bad feedback since the last 5-6 years. 3. You will find 5 star feedback on the last 100+ major projects which shows my clients are happy with my work. Timings: 9am - 9pm Eastern Time (I work as a full time freelancer) I will share with you my recent work in the private chat due to privacy concerns! Please start the chat to discuss it further.
$1 500 USD 1 päivässä
0,0
0,0

I’ve reviewed your project and understand you’re looking for a thorough conversion of your Siemens S7 program to RSLogix 5000 while preserving existing functionality. With extensive experience in PLC programming and system integrations, I'll ensure all real-time controls for motors, valves, and alarms are perfectly mirrored in the new platform. Additionally, I will provide a detailed cross-reference document to map all original S7 tags to their new equivalents, ensuring seamless operation and clarity in your ControlLogix environment. I anticipate having the project ready for you within 15 days, and I'm confident that it will compile without errors. What specific improvements are you envisioning for clarity in the rung descriptions?
$1 500 USD 1 päivässä
0,0
0,0

Hi, there. I appreciate the opportunity to support your migration from Siemens S7 to RSLogix 5000 for your production line control system. Having extensive experience with both Siemens Step 7 and Allen-Bradley platforms, I am well-versed in translating complex logic, sequences, and safety functions between these environments. Your requirements for precise replication of all control logic, alarms, and safety interlocks—including the crucial ESTOP and guard logic—will be addressed by methodically analyzing the S7 project archive, I/O mappings, and converting each function block (SCL and LAD) to ensure full operational equivalence on the ControlLogix platform. I will provide a comprehensive cross-reference document mapping all original tags, DBs, and FCs to their new RSLogix counterparts, ensuring traceability and ease of future maintenance. Furthermore, I will ensure full compliance with Allen-Bradley’s safety standards and adapt the drive communications from Profinet (G120 VFDs) to Ethernet/IP, using best practices for structured, commented, and maintainable code. You can expect a Studio 5000 project that compiles cleanly, maintains or improves clarity in all documentation, and is fully aligned with your plant’s operational needs. Best regards Boris
$1 500 USD 10 päivässä
0,0
0,0

Hey there, What exact Allen-Bradley target are we coding for: ControlLogix model, firmware version, and is it GuardLogix for safety? Are the G120 drives staying with Profinet, or will you use a Profinet to Ethernet/IP gateway or change to Ethernet/IP drives? I can port your Step7 project to Studio 5000 with the same sequences, timers, interlocks, and alarms. My approach is: map I/O and tags first, then rebuild each FC FB as Logix routines and AOIs, keep rung comments and descriptions, and match the scan time behavior. I will deliver a cross-reference table for every DB, FC, and tag to the new controller or program tags. For safety: I will convert the E-Stop and guard logic to the Allen-Bradley safety equivalent. If CIP Safety is not possible with G120, we can use hardwired STO and safety I/O with GuardLogix. For drive comms: I will mirror the start stop, speed setpoints, status words, faults, and alarms using Ethernet/IP, based on your telegram mapping and I/O list. Hope to discuss more on chat. Best, Taras
$2 250 USD 7 päivässä
0,0
0,0

As a freelancer with a multidisciplinary background, my core skills in Electrical Engineering and Data Automation make me an ideal candidate to undertake your project. I understand the importance of precision and seamless replication when it comes to translating code across platforms. Having worked with RSLogix5000, Allen-Bradley systems, and Siemens S7 platforms previously, I am proficient in working with both and have successfully executed similar system conversions. My extensive experience in Full-Stack Web & App Development alongside my strong affinity for Data Entry & Automation will be particularly advantageous as I ensure your existing tag list is mirrored accurately and all routine names, comments, and rung descriptions are preserved in the translated file. Moreover, I can leverage my knowledge of Australia-specific standards and compliance - crucial aspects for any manufacturing operation. Let's establish a collaborative approach that ensures your vision, goals, and expectations are met throughout the process. From delivering detailed cross-reference documentation to effectively porting Siemens profisafe to an Allen Bradley safety-equivalent mechanism, I'm dedicated to providing meticulous solutions that seamlessly integrate your machinery for optimized production on the ControlLogix target platform. Ready to bring your ideas to life? Let's get started!
$3 000 USD 7 päivässä
0,0
0,0

Hello, no problem. I am a senior controls engineer with extensive experience in PLC program conversion between Siemens (Step 7) and Allen-Bradley (RSLogix 5000 / Studio 5000) platforms, including complex safety and drive communication protocols. I will take your complete S7 project archive and I/O lists and reproduce the exact functionality in a new RSLogix 5000 project for a ControlLogix controller. The conversion will include: porting all real-time control logic for motors, valves, and solenoids; converting Siemens Profisafe safety logic to Allen-Bradley GuardLogix equivalents for all E-STOPs; and re-implementing all G120 VFD communications from Profinet to Ethernet/IP using appropriate AOIs. I will provide a fully commented, error-free RSLogix 5000 project file, a detailed cross-reference document mapping all original S7 tags/DBs/FCs to the new tags, and confirmation of compilation and clarity. I am ready to begin as soon as you share the Step 7 archive and I/O lists. Sincerely, Lorenzo
$1 500 USD 4 päivässä
0,0
0,0

Edison, United States
Liittynyt helmik. 27, 2026
$250-750 AUD
$30-250 USD
₹2000-4000 INR
$30-250 USD
₹600-1500 INR
₹12500-37500 INR
$15-25 USD/ tunnissa
$750-1500 USD
₹500000-1000000 INR
min €36 EUR/ tunnissa
€30-250 EUR
$250-750 USD
$750-1500 USD
$30-250 USD
$750-1500 USD
₹1500-12500 INR
$30-250 USD
£20-250 GBP
₹12500-37500 INR
₹12500-37500 INR