A Low RPM Alarm Using 74HC or 4000 Series Logic. No MCU allowed.

  • Tila: Closed
  • Palkinto: $100
  • Vastaanotetut työt: 13
  • Voittaja: osamaelkomy

Kilpailun tehtävänanto

I need a simple circuit using common hardware parts that measures the high width of a TTL pulse and if it exceeds 3 seconds a logic output is set high as an alarm.

If the pulse becomes shorter than 3 seconds the logic output is set low so alarm is turned off.

A 32768Hz clock is available. Maybe a 74HC series binary counter might work. Or specify your own clock generator.

We want simple 74HC logic, or 4000 logic. Not MCU and not FPGA.

When we choose the circuit we will build it to confirm it works before awarding prize.

Suositellut taidot

Työnantajan palaute

“Excellent Freelancer and good communication”

Profiilikuva tonyoatlands, Australia.

Kilpailun parhaat työt

Näytä lisää töitä

Julkinen selvennystaulu

  • tonyoatlands
    Kilpailun järjestäjä
    • 2 kuukautta sitten

    Thank you every body for your ideas. But NO ONE has provided a schematic design we can build.

    We have been given ideas only. Please provide a schematic with component values.

    • 2 kuukautta sitten
  • tonyoatlands
    Kilpailun järjestäjä
    • 2 kuukautta sitten

    We already know the job can be done. We don't need ideas and suggestions. We need a working design that we can build and test. Today we have four entries. No entry shows a working complete design!

    • 2 kuukautta sitten
    1. Muzafarbaloch
      Muzafarbaloch
      • 2 kuukautta sitten

      Sir! here you are kindly check #8 . it contains the complete working circuit design. Thanks

      • 2 kuukautta sitten
  • Muzafarbaloch
    Muzafarbaloch
    • 2 kuukautta sitten

    Certainly, you can use a 74HC4040 binary counter and other basic components to create a circuit that measures the width of a TTL pulse. Sir Kindly check my entry #8 . everything is mentioned there.

    • 2 kuukautta sitten
  • osamaelkomy
    osamaelkomy
    • 2 kuukautta sitten

    I'm confused about your requirements for this contest.!
    I gave you the design schematic and a simulation. The simulation confirmed that the design works perfectly with 74HCXX logic chips. What else do you need ?

    • 2 kuukautta sitten
    1. osamaelkomy
      osamaelkomy
      • 2 kuukautta sitten

      There are other options to replace 74HC123 that can generate the 3s pulse like 74HC4538. Does using MMV acceptable ? or you prefer counter solution ?

      • 2 kuukautta sitten
    2. osamaelkomy
      osamaelkomy
      • 2 kuukautta sitten

      Other thing about circuit behavior, when the alarm signal is activated ( if the PW > 3s), what should happen when the PW returns to normal condition (PW < 3s)? automatically deactivate the alarm, or provide manual deactivation (Reset)?

      • 2 kuukautta sitten

Näytä lisää kommentteja

Kuinka päästä alkuun kilpailuiden kanssa

  • Ilmoita kilpailusi

    Ilmoita kilpailusi Nopeaa ja helppoa

  • Saat valtavasti töitä

    Vastaanota tonnikaupalla osallistumisia Ympäri maailmaa

  • Myönnä palkinto parhaalle työlle

    Myönnä palkinto parhaalle työlle Lataa tiedostot - Helppoa!

Ilmoita kilpailu nyt tai liity tänään!